Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Jan;37(1):100-11.
doi: 10.1183/09031936.00114810. Epub 2010 Sep 16.

Interferon-γ release assays for the diagnosis of active tuberculosis: a systematic review and meta-analysis

Affiliations
Free article
Meta-Analysis

Interferon-γ release assays for the diagnosis of active tuberculosis: a systematic review and meta-analysis

M Sester et al. Eur Respir J. 2011 Jan.
Free article

Erratum in

  • Eur Respir J. 2012 Mar;39(3):793

Abstract

Interferon-γ release assays (IGRAs) are now established for the immunodiagnosis of latent infection with Mycobacterium tuberculosis in many countries. However, the role of IGRAs for the diagnosis of active tuberculosis (TB) remains unclear. Following preferred reporting items for systematic reviews and meta-analyses (PRISMA) and quality assessment of diagnostic accuracy studies (QUADAS) guidelines, we searched PubMed, EMBASE and Cochrane databases to identify studies published in January 2001-November 2009 that evaluated the evidence of using QuantiFERON-TB® Gold in-tube (QFT-G-IT) and T-SPOT.TB® directly on blood or extrasanguinous specimens for the diagnosis of active TB. The literature search yielded 844 studies and 27 met the inclusion criteria. In blood and extrasanguinous fluids, the pooled sensitivity for the diagnosis of active TB was 80% (95% CI 75-84%) and 48% (95% CI 39-58%) for QFT-G-IT, and 81% (95% CI 78-84%) and 88% (confirmed and unconfirmed cases) (95% CI 82-92%) for T-SPOT.TB®, respectively. In blood and extrasanguinous fluids, the pooled specificity was 79% (95% CI 75-82%) and 82% (95% CI 70-91%) for QFT-G-IT, and 59% (95% CI 56-62%) and 82% (95% CI 78-86%) for T-SPOT.TB®, respectively. Although the diagnostic sensitivities of both IGRAs were higher than that of tuberculin skin tests, it was still not high enough to use as a rule out test for TB. Positive evidence for the use of IGRAs in compartments other than blood will require more independent and carefully designed prospective studies.