Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Dec;109(6):1644-52.
doi: 10.1152/japplphysiol.00656.2010. Epub 2010 Sep 16.

Direct comparison of in vivo Achilles tendon moment arms obtained from ultrasound and MR scans

Affiliations
Free article
Comparative Study

Direct comparison of in vivo Achilles tendon moment arms obtained from ultrasound and MR scans

Florian Fath et al. J Appl Physiol (1985). 2010 Dec.
Free article

Abstract

Accurate and reliable estimation of muscle moment arms is a prerequisite for the development of musculoskeletal models. Numerous techniques are available to estimate the Achilles tendon moment arm in vivo. The purposes of this study were 1) to compare in vivo Achilles tendon moment arms obtained using the center of rotation (COR) and tendon excursion (TE) methods and 2) to assess the reliability of each method. For the COR method, magnetic resonance (MR) images from nine participants were obtained at ankle angles of -15°, 0°, and +15° and analyzed using Reuleaux' method. For the TE method, the movement of the gastrocnemius medialis-Achilles tendon junction was recorded using ultrasonography as the ankle was passively rotated through its range of motion. The Achilles tendon moment arm was obtained by differentiation of tendon displacement with respect to ankle angular excursion using seven different differentiation techniques. Moment arms obtained using the COR method were significantly greater than those obtained using the TE method (P < 0.01), but results from both methods were well correlated. The coefficient of determination between moment arms derived from the COR and TE methods was highest when tendon displacement was linearly differentiated over a ± 10° interval (R(2) = 0.94). The between-measurement coefficient of variation was 3.9% for the COR method and 4.5-9.7% for the TE method, depending on the differentiation technique. The high reliabilities and strong relationship between methods demonstrate that both methods are robust against their limitations. The large absolute between-method differences (∼ 25-30%) in moment arms have significant implications for their use in musculoskeletal models.

PubMed Disclaimer

Publication types

LinkOut - more resources