A review of electrocardiogram filtering
- PMID: 20851409
- DOI: 10.1016/j.jelectrocard.2010.07.007
A review of electrocardiogram filtering
Abstract
Analog filtering and digital signal processing algorithms in the preprocessing modules of an electrocardiographic device play a pivotal role in providing high-quality electrocardiogram (ECG) signals for analysis, interpretation, and presentation (display, printout, and storage). In this article, issues relating to inaccuracy of ECG preprocessing filters are investigated in the context of facilitating efficient ECG interpretation and diagnosis. The discussion covers 4 specific ECG preprocessing applications: anti-aliasing and upper-frequency cutoff, baseline wander suppression and lower-frequency cutoff, line frequency rejection, and muscle artifact reduction. Issues discussed include linear phase, aliasing, distortion, ringing, and attenuation of desired ECG signals. Due to the overlapping power spectrum of signal and noise in acquired ECG data, frequency selective filters must seek a delicate balance between noise removal and deformation of the desired signal. Most importantly, the filtering output should not adversely impact subsequent diagnosis and interpretation. Based on these discussions, several suggestions are made to improve and update existing ECG data preprocessing standards and guidelines.
Copyright © 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Real time ECG artifact removal for myoelectric prosthesis control.Physiol Meas. 2007 Apr;28(4):397-413. doi: 10.1088/0967-3334/28/4/006. Epub 2007 Mar 20. Physiol Meas. 2007. PMID: 17395995
-
ECG signal denoising and baseline wander correction based on the empirical mode decomposition.Comput Biol Med. 2008 Jan;38(1):1-13. doi: 10.1016/j.compbiomed.2007.06.003. Epub 2007 Jul 31. Comput Biol Med. 2008. PMID: 17669389
-
Noise cancellation signal processing method and computer system for improved real-time electrocardiogram artifact correction during MRI data acquisition.IEEE Trans Biomed Eng. 2007 Apr;54(4):630-40. doi: 10.1109/TBME.2006.889174. IEEE Trans Biomed Eng. 2007. PMID: 17405370
-
What is inside the electrocardiograph?J Electrocardiol. 2008 Jan-Feb;41(1):8-14. doi: 10.1016/j.jelectrocard.2007.08.059. J Electrocardiol. 2008. PMID: 18191652 Review.
-
Noise and baseline wandering suppression of ECG signals by morphological filter.J Med Eng Technol. 2010 Feb;34(2):87-96. doi: 10.3109/03091900903336886. J Med Eng Technol. 2010. PMID: 20028196 Review.
Cited by
-
Detection and removal of pacing artifacts prior to automated analysis of 12-lead ECG.Comput Biol Med. 2021 Jun;133:104396. doi: 10.1016/j.compbiomed.2021.104396. Epub 2021 Apr 19. Comput Biol Med. 2021. PMID: 33872969 Free PMC article.
-
A hybrid cardiovascular arrhythmia disease detection using ConvNeXt-X models on electrocardiogram signals.Sci Rep. 2024 Dec 5;14(1):30366. doi: 10.1038/s41598-024-81992-w. Sci Rep. 2024. PMID: 39638880 Free PMC article.
-
A Wearable Wrist Band-Type System for Multimodal Biometrics Integrated with Multispectral Skin Photomatrix and Electrocardiogram Sensors.Sensors (Basel). 2018 Aug 20;18(8):2738. doi: 10.3390/s18082738. Sensors (Basel). 2018. PMID: 30127306 Free PMC article.
-
A low-pass filter of 300 Hz improved the detection of pacemaker spike on remote and bedside electrocardiogram.Chin Med J (Engl). 2019 Mar 5;132(5):534-541. doi: 10.1097/CM9.0000000000000110. Chin Med J (Engl). 2019. PMID: 30807352 Free PMC article.
-
Two-stage motion artefact reduction algorithm for electrocardiogram using weighted adaptive noise cancelling and recursive Hampel filter.PLoS One. 2018 Nov 20;13(11):e0207176. doi: 10.1371/journal.pone.0207176. eCollection 2018. PLoS One. 2018. PMID: 30457996 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources