Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
- PMID: 20859478
- PMCID: PMC2936093
- DOI: 10.4103/0972-0707.66714
Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
Abstract
Objective: This study aims to evaluate the effect of saliva contamination on the shear bond strength of two self-etch dentine bonding systems and also investigate the effect of decontamination procedure on the recovery of bond strength.
Materials and methods: Sixty premolars extracted for orthodontic reason were obtained and the buccal surfaces of teeth were reduced to create a flat dentine surface. The samples were randomly divided into three sub-groups for AdheSE (ASE) (Ivoclar - Vivadent, Schaan, Liechtenstein) and three sub-groups for Adper Prompt Self-Etch Adhesive (ADP) (3M ESPE, St Paul, MN, USA) of 10 each. For AdheSE (ASE); ASE-I was the control group (primer applied to fresh dentine surface), ASE-II was the contamination group (primer applied, followed by saliva contamination and then air dried) and ASE-III was the decontamination group (primer applied, followed by saliva contamination, air dried and then primer reapplied). For Adper Prompt (ADP); ADP-I was the control group (self-etch adhesive applied to fresh dentine surface), ADP-II was the contamination group (self-etch adhesive applied, followed by saliva contamination and then air dried) and ADP-III was the decontamination group (self-etch adhesive applied, followed by saliva contamination, air dried and then self-etch adhesive reapplied). Followed by the bonding procedure, a 5 mm composite resin block with Filtek P-60 (3M ESPE, St Paul, MN, USA) was built on the substrate. Shear bond strength (SBS) was tested with Instron Universal testing machine (Instron Corporation, Canton, MA, USA) with a cross head speed of 1 mm per minute. Data obtained was subjected to one way ANOVA test, while the inter group comparison was made using Tukey's multiple comparison and Unpaired t-test.
Results: In AdhSE group (ASE), the sub-group ASE-II (contamination group) [5.4 ± 2.2 MPa] showed lower SBS than ASE-I [11.8 ± 2.6 MPa] and ASE-III [8.9 ± 3.3 MPa], which was statistically significant. There was no significant difference in the bond strength between the ASE-I (control group) and ASE-III (decontamination group). In Adper Prompt group (ADP), there was a severe decrease of bond strength in ADP-II (contamination group) [4.6 ± 1.1 MPa] when compared to ADP-I (control group) [7.4 ± 1.4 MPa] and ADP-III (decontamination subgroup) [14.1 ± 2.2 MPa] which was statistically significant. The bond strength of ADP-III wherein Adper Prompt bonding agent was reapplied after salivary contamination was found to be statistically significant than ADP-I and ADP-II.
Conclusion: Saliva contamination reduces the dentine bond strength of both the self-etch systems; AdheSE and Adper Prompt. Re-application of the primer for the AdheSE and re-application of the adhesive for the Adper Prompt after air drying the saliva off can recover the dentine bond strength. In the Adper Prompt group, the added application of adhesives to decontaminate saliva not only recovered the bond strength but also improved it significantly.
Keywords: Decontamination procedure; salivary contamination; self-etch adhesive system; shear bond strength.
Conflict of interest statement
Figures
Similar articles
-
The long-term consequence of salivary contamination at various stages of adhesive application and clinically feasible remedies to decontaminate.Clin Oral Investig. 2020 Dec;24(12):4413-4426. doi: 10.1007/s00784-020-03307-3. Epub 2020 Jun 9. Clin Oral Investig. 2020. PMID: 32519235 Free PMC article.
-
Effect of saliva contamination on the microshear bond strength of one-step self-etching adhesive systems to dentin.Oper Dent. 2006 Jan-Feb;31(1):127-34. doi: 10.2341/04-206. Oper Dent. 2006. PMID: 16536204 Clinical Trial.
-
The influence of salivary contamination on shear bond strength of dentin adhesive systems.Oper Dent. 2004 Jul-Aug;29(4):437-42. Oper Dent. 2004. PMID: 15279484
-
The effect of saliva contamination on shear bond strength of orthodontic brackets when using a self-etch primer.Angle Orthod. 2002 Dec;72(6):554-7. doi: 10.1043/0003-3219(2002)072<0554:TEOSCO>2.0.CO;2. Angle Orthod. 2002. PMID: 12518947
-
The Use of Warm Air for Solvent Evaporation in Adhesive Dentistry: A Meta-Analysis of In Vitro Studies.J Funct Biomater. 2023 May 20;14(5):285. doi: 10.3390/jfb14050285. J Funct Biomater. 2023. PMID: 37233396 Free PMC article. Review.
Cited by
-
Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems.J Dent Biomater. 2016 Sep;3(3):292-298. J Dent Biomater. 2016. PMID: 28959756 Free PMC article.
-
Evaluation of Shear Bond Strength of Total- and Self-etching Adhesive Systems after Application of Chlorhexidine to Dentin Contaminated with a Hemostatic Agent.J Dent (Shiraz). 2015 Sep;16(3):175-81. J Dent (Shiraz). 2015. PMID: 26331146 Free PMC article.
-
Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study.J Conserv Dent. 2012 Jul;15(3):270-3. doi: 10.4103/0972-0707.97956. J Conserv Dent. 2012. PMID: 22876017 Free PMC article.
-
Effect of different decontamination procedures from a saliva-contaminated cured bonding system (Single Bond).Dent Res J (Isfahan). 2012 Jul;9(4):399-403. Dent Res J (Isfahan). 2012. PMID: 23162579 Free PMC article.
-
The long-term consequence of salivary contamination at various stages of adhesive application and clinically feasible remedies to decontaminate.Clin Oral Investig. 2020 Dec;24(12):4413-4426. doi: 10.1007/s00784-020-03307-3. Epub 2020 Jun 9. Clin Oral Investig. 2020. PMID: 32519235 Free PMC article.
References
-
- Jhonson ME, Burgess JO, Hermesch CB, Buikema DJ. Saliva contamination of Dentine bonding agents. Oper Dent. 1994;19:205–10. - PubMed
-
- Van Meerbeck BV, Inoue S, Perdigao S, Lambrechts P, Vanherle G. Enamel and dentin adhesion. In: Summitt JB, Robbins JW, Schwartz RS, editors. Fundamentals of Operative Dentistry. 2nd ed. Chicago: Illinios Quintessence Publishing Co Inc; 2000. pp. 178–221.
-
- Xie J, Powers JM, McGuckin RS. In vitro bond strength of two nonadhesives to enamel and dentin under normal and contaminated conditions. Dent Materials. 1993;9:295–9. - PubMed
-
- Hitmi L, Attal JP, Degrange M. Influence of the time point of salivary contamination on dentin shear bond strength of 3 dentin adhesive systems. J Adhes Dent. 1999;1:219–32. - PubMed
-
- Mojon P, Kaltio R, Feduik D, Hawbolt EB, McEntee MI. Short term contamination of luting cements by water and saliva. Dent Materials. 1996;12:83–7. - PubMed