Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Oct;28(5):603-11.
doi: 10.1089/pho.2009.2544. Epub 2010 Sep 23.

Low-level laser therapy with a pulsed infrared laser accelerates second-degree burn healing in rat: a clinical and microbiologic study

Affiliations
Comparative Study

Low-level laser therapy with a pulsed infrared laser accelerates second-degree burn healing in rat: a clinical and microbiologic study

Ali Ezzati et al. Photomed Laser Surg. 2010 Oct.

Abstract

Objective: This study was carried out to investigate the influence of pulsed-wave low-level laser therapy (LLLT) on the healing of a deep second-degree burn model in rat.

Background data: Review of literature indicates that LLLT has a biostimulatory effect on wound healing; however, no clear recommendation can yet be made.

Methods: Two deep second-degree burns were made in the skin of 67 rats. Rats were divided into four groups. In the first group (control), the proximal burn were received LLLT with shot down laser; in the second and third groups, proximal burns were treated with a 3,000-Hz pulsed infrared diode laser with 2.3 and 11.7 J/cm(2) energy densities, respectively. In the fourth group, the proximal burns were treated topically with 0.2% nitrofurazone. The distal burn of all groups was considered the control burn. The response to treatment was assessed both microbiologically and macroscopically.

Results: The incidence of Staphylococcus aureus decreased significantly in group 3 in comparison with group 1 on day 28 (χ(2) test, p = 0.05). Analysis of variance showed that LLLT with 11.7 J/cm (2) significantly increased the wound-closure rate at 2 weeks (0.915 ± 0.310) and 3 weeks (0.677 ± 0.397) after burning compared with placebo burns (1.413 ± 0.319; 1.116 ± 0.436, respectively) ANOVA-LSD test, p = 0.045 and p = 0.046 respectively. Independent sample t tests showed that LLLT with 11.7 J/cm (2) significantly increased the wound-closure rate at 4 weeks after burning (0.211 ± 0.146) compared with the control burns (0.707 ± 0.480) p = 0.039.

Conclusions: Pulsed LLLT with 11.7 J/cm(2)/890 nm of a deep second-degree burn model in rat significantly increased the rate of wound closure compared with control burns.

PubMed Disclaimer

Publication types

LinkOut - more resources