Multiplex detection of IgM and IgG class antibodies to Toxoplasma gondii, rubella virus, and cytomegalovirus using a novel multiplex flow immunoassay
- PMID: 20861325
- PMCID: PMC2976082
- DOI: 10.1128/CVI.00332-10
Multiplex detection of IgM and IgG class antibodies to Toxoplasma gondii, rubella virus, and cytomegalovirus using a novel multiplex flow immunoassay
Abstract
The goal of this study was to evaluate the BioPlex 2200 Toxoplasma, rubella, and cytomegalovirus (CMV) (ToRC) IgG and IgM multiplex immunoassays (Bio-Rad Laboratories, Hercules, CA) and compare the results to those of conventional testing by enzyme immunoassay (EIA) and enzyme-linked fluorescent assay (ELFA). Serum specimens (n = 600) submitted for routine ToRC IgG and IgM testing by EIA (SeraQuest, Doral, FL; Diamedix, Miami, FL) or ELFA (Vidas; bioMérieux, Durham, NC) were also tested by the BioPlex ToRC multiplex immunoassays. Samples showing discordant results were retested by both methods, with further discrepancies being arbitrated by a third assay. Following repeat testing, the BioPlex Toxoplasma, rubella, and CMV IgG assays demonstrated agreements of 98.7 (592/600 specimens), 93.3 (560/600 specimens), and 98.3% (590/600 specimens), respectively, while the ToRC IgM assays yielded agreements of 91.2 (547/600 specimens), 87.3 (524/600 specimens), and 95.2% (571/600 specimens), respectively. The BioPlex ToRC IgG assays provided results comparable to EIA/ELFA results, with kappa coefficients showing near-perfect agreement for the Toxoplasma (κ = 0.94) and CMV (κ = 0.97) IgG assays and substantial agreement for the rubella IgG assay (κ = 0.66). The BioPlex ToRC IgM assays showed lower specificity with only slight agreement for Toxoplasma IgM (κ = 0.07), poor agreement for rubella IgM (κ = -0.03), and moderate agreement for CMV IgM (κ = 0.55). Both the BioPlex IgG and IgM assays reduced turnaround time (1.7 h versus 5.5 h by EIA/ELFA for 100 specimens) and eliminated the necessity to manually pipette or aliquot specimens prior to testing.
Similar articles
-
Evaluation of the Bio-Rad BioPlex 2200 Toxoplasma gondii IgM Multiplex Flow Immunoassay.J Appl Lab Med. 2019 May;3(6):1022-1027. doi: 10.1373/jalm.2018.026906. Epub 2018 Aug 13. J Appl Lab Med. 2019. PMID: 31639693
-
Evaluation of the Bio-Rad BioPlex Measles, Mumps, Rubella, and Varicella-Zoster Virus IgG multiplex bead immunoassay.Clin Vaccine Immunol. 2011 Sep;18(9):1524-6. doi: 10.1128/CVI.05207-11. Epub 2011 Jul 27. Clin Vaccine Immunol. 2011. PMID: 21795463 Free PMC article.
-
Performance of the BioPlex 2200 flow immunoassay in critical cases of serodiagnosis of toxoplasmosis.Clin Vaccine Immunol. 2014 Apr;21(4):496-500. doi: 10.1128/CVI.00624-13. Epub 2014 Jan 29. Clin Vaccine Immunol. 2014. PMID: 24477853 Free PMC article.
-
Seroprevalence and age-related susceptibility of TORCH infections in childbearing age women: A 5-year cross-sectional retrospective study and a literature review.J Infect Public Health. 2024 Oct;17(10):102537. doi: 10.1016/j.jiph.2024.102537. Epub 2024 Aug 30. J Infect Public Health. 2024. PMID: 39255545 Review.
-
Incidence, clinical spectrum, and outcome of intrauterine infections in neonates.J Trop Pediatr. 2000 Jun;46(3):155-9. doi: 10.1093/tropej/46.3.155. J Trop Pediatr. 2000. PMID: 10893916 Review.
Cited by
-
Evaluation of a novel array-based toxoplasma, rubella, cytomegalovirus, and herpes simplex virus IgG enzyme linked immunosorbent assay and its comparison with virion/serion enzyme linked immunosorbent assays.Ann Lab Med. 2014 Jan;34(1):38-42. doi: 10.3343/alm.2014.34.1.38. Epub 2013 Dec 6. Ann Lab Med. 2014. PMID: 24422194 Free PMC article.
-
Preliminary multiplex microarray IgG immunoassay for the diagnosis of toxoplasmosis and rubella.Mem Inst Oswaldo Cruz. 2017 Jun;112(6):428-436. doi: 10.1590/0074-02760160509. Mem Inst Oswaldo Cruz. 2017. PMID: 28591403 Free PMC article.
-
Seroepidemiology of Toxoplasma in a coastal region of Haiti: multiplex bead assay detection of immunoglobulin G antibodies that recognize the SAG2A antigen.Epidemiol Infect. 2015 Feb;143(3):618-30. doi: 10.1017/S0950268814001216. Epidemiol Infect. 2015. PMID: 25600668 Free PMC article.
-
Serological evidence of acute rubella infection among under-fives in Mwanza: a threat to increasing rates of congenital rubella syndrome in Tanzania.Ital J Pediatr. 2016 May 25;42(1):54. doi: 10.1186/s13052-016-0264-5. Ital J Pediatr. 2016. PMID: 27225802 Free PMC article.
-
Detection of Anti-Toxoplasma gondii Antibodies in Human Sera Using Synthetic Glycosylphosphatidylinositol Glycans on a Bead-Based Multiplex Assay.Anal Chem. 2019 Sep 3;91(17):11215-11222. doi: 10.1021/acs.analchem.9b02154. Epub 2019 Aug 22. Anal Chem. 2019. PMID: 31401830 Free PMC article.
References
-
- Abdel-Fattah, S. A., A. Bhat, S. Illanes, J. L. Bartha, and D. Carrington. 2005. TORCH test for fetal medicine indications: only CMV is necessary in the United Kingdom. Prenat. Diagn. 25:1028-1031. - PubMed
-
- Averhoff, F., J. Zucker, C. Vellozzi, S. Redd, C. Woodfill, S. Waterman, J. Baggs, M. Weinberg, A. Rodriquez-Lainz, V. Carrion, C. Goto, and S. E. Reef. 2006. Adequacy of surveillance to detect endemic rubella transmission in the United States. Clin. Infect. Dis. 43(Suppl. 3):S151-S157. - PubMed
-
- Doern, G. V., L. Robbie, and L. Marrama. 1994. Comparison of two enzyme immunoassays and two latex agglutination assays for detection of cytomegalovirus antibody. Diagn. Microbiol. Infect. Dis. 20:109-112. - PubMed