Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993;3(4):236-44.
doi: 10.1016/1050-6411(93)90013-M.

EMG signal amplitude normalization technique in stretch-shortening cycle movements

Affiliations

EMG signal amplitude normalization technique in stretch-shortening cycle movements

G T Allison et al. J Electromyogr Kinesiol. 1993.

Abstract

Analysis of functional movements using surface electromyography (EMG) often involves recording both eccentric and concentric muscle activity during a stretch-shorten cycle (SSC). The techniques used for amplitude normalization are varied and are independent of the type of muscle activity involved. The purpose of this study was: (i) to determine the effect of 11 amplitude normalization techniques on the coefficient of variation (CV) during the eccentric and concentric phases of the SSC; and (ii) to establish the effect of the normalization techniques on the EMG signal under variable load and velocity. The EMG signal of the biceps brachii of eight normal subjects was recorded under four SSC conditions and three levels of isometric contraction. The 11 derived normalization values were total rms, mean rms and peak rms (100 ms time constant) for the isometric contractions and the mean rms and peak rms values of the ensemble values for each set of isotonic contractions. Normalization using maximal voluntary isometric contractions (MVIC), irrespective of rms processing (total, mean or peak), demonstrated greater CV above the raw data for both muscle actions. Mean ensemble values and submaximal isometric recordings reduced the CV of concentric data. No amplitude normalization technique reduced the CV for eccentric data under loaded conditions. An ANOVA demonstrated significant (P < 0.01) main effects for load and velocity on concentric raw data and an interaction (P < 0.05) for raw eccentric data. No significant effects were demonstrated for changes in velocity when the data were normalized using mean rms values. The reduction of the CV should not be at the expense of true biological variance and current normalization techniques poorly serve the analysis of eccentric muscle activity during the SSC.

PubMed Disclaimer

LinkOut - more resources