Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography
- PMID: 20872188
- DOI: 10.1007/s12194-010-0105-y
Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography
Abstract
Our aim in this study was to determine an optimal delay time of hepatic arterial phase (HAP) imaging of hypervascular hepatocellular carcinomas (HCCs) in dynamic contrast-enhanced MDCT (DCE-CT) by use of the bolus-tracking method. The time-enhancement curves (TECs) of the aorta and the contrast of the hepatic arterial and portal system (APC) in the pharmacokinetic analysis were calculated. The clinical study included 41 patients with known or suspected HCC who underwent DCE-CT. The TECs of the aorta and the tumor-liver contrast (TLC) in the clinical study were calculated. On pharmacokinetic analysis, the peak aortic enhancement and the peak APC simulated under conditions of an injection duration of 30 s and an iodine load of 500 mg I/kg body weight were observed 18.5 and 22.5 s, respectively, after the trigger threshold (increased CT value 100 Hounsfield units), respectively. In the clinical study, the peak aortic enhancement and the peak TLC were observed 17.2 and 24.8 s after the trigger threshold, respectively. The optimal delay times until peak aortic enhancement and peak HAP were 15-17 and 19-21 s after the trigger threshold, respectively, under the following conditions: injection dose, 500 mg I/kg body weight; injection duration, 30 s; acquisition time, 5 s; and the trigger threshold. In addition, the peak TLC was achieved 4-7 s after the time to peak aortic enhancement.
Similar articles
-
MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases.AJR Am J Roentgenol. 2006 Jul;187(1):W25-32. doi: 10.2214/AJR.04.1878. AJR Am J Roentgenol. 2006. PMID: 16794136 Clinical Trial.
-
Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT.Radiat Med. 2007 Jul;25(6):278-88. doi: 10.1007/s11604-007-0138-2. Epub 2007 Jul 27. Radiat Med. 2007. PMID: 17634881
-
Hypervascular hepatocellular carcinomas: bolus tracking with a 40-detector CT scanner to time arterial phase imaging.Radiology. 2007 Apr;243(1):140-7. doi: 10.1148/radiol.2431060069. Epub 2007 Feb 28. Radiology. 2007. PMID: 17329690 Clinical Trial.
-
Multiphasic contrast-enhanced multidetector-row CT of liver: contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material.Eur J Radiol. 2006 May;58(2):165-76. doi: 10.1016/j.ejrad.2005.11.037. Epub 2006 Jan 18. Eur J Radiol. 2006. PMID: 16417983 Review.
-
CT Imaging of early hepatocellular carcinoma and the natural outcome of hypoattenuating nodular lesions in chronic liver disease.Oncology. 2007;72 Suppl 1:83-91. doi: 10.1159/000111712. Epub 2007 Dec 13. Oncology. 2007. PMID: 18087187 Review.
Cited by
-
Transient washout of hepatic hemangiomas: Potential pitfall mimicking malignancy.Radiol Case Rep. 2016 Apr 6;11(2):62-6. doi: 10.1016/j.radcr.2016.02.010. eCollection 2016 Jun. Radiol Case Rep. 2016. PMID: 27257451 Free PMC article.
-
Optimized scan delay for late hepatic arterial or pancreatic parenchymal phase in dynamic contrast-enhanced computed tomography with bolus-tracking method.Br J Radiol. 2021 Jun 1;94(1122):20210315. doi: 10.1259/bjr.20210315. Epub 2021 May 6. Br J Radiol. 2021. PMID: 33956484 Free PMC article.
-
A new method with variable injection parameters in contrast-enhanced CT: a phantom study for evaluating an aortic peak enhancement.Radiol Phys Technol. 2015 Jul;8(2):248-57. doi: 10.1007/s12194-015-0314-5. Epub 2015 May 1. Radiol Phys Technol. 2015. PMID: 25930969
-
Computed tomography pulmonary angiography and venography with a low dose of contrast medium.Radiol Phys Technol. 2019 Mar;12(1):61-68. doi: 10.1007/s12194-018-00492-5. Epub 2018 Dec 10. Radiol Phys Technol. 2019. PMID: 30536083 Clinical Trial.
-
Challenges to protocol optimization due to unexpected variation of CT contrast dose amount and flow.J Digit Imaging. 2013 Jun;26(3):402-5. doi: 10.1007/s10278-012-9544-9. J Digit Imaging. 2013. PMID: 23143417 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical