Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010;24(5):300-4.
doi: 10.1002/jcla.20405.

Re-evaluation of cord blood arterial and venous reference ranges for pH, pO(2), pCO(2), according to spontaneous or cesarean delivery

Affiliations

Re-evaluation of cord blood arterial and venous reference ranges for pH, pO(2), pCO(2), according to spontaneous or cesarean delivery

K Kotaska et al. J Clin Lab Anal. 2010.

Abstract

Umbilical cord blood gas analysis (pO(2) and pCO(2)) is now recommended in all high-risk baby deliveries and in some centers it is performed routinely following all deliveries. The aim of this study was to re-evaluate cord blood arterial and venous reference ranges for pH, pO(2), pCO(2) in newborns, delivered by spontaneous vaginal delivery (SVD) and by cesarean section (CS) performed in Faculty Hospital Motol. Two groups of subjects were selected for the study. Group I consisted of 303 newborns with SVD. Group II consisted of 189 newborns delivered by cesarean section. Cord blood samples were analyzed for standard blood gas and pH, using the analytical device Rapid Lab 845 and Rapid Lab 865. We obtained reference values expressed as range (lower and upper reference value expressed as 2.5 and 97.5 percentiles) for cord blood in newborns with SVD: arterial cord blood: pH=7.01-7.39; pCO(2)=4.12-11.45 kPa; pO(2)=1.49-5.06 kPa; venous cord blood: pH=7.06-7.44; pCO(2)=3.33-9.85 kPa; pO(2)=1.80-6.29 kPa. We also obtained reference values for cord blood in newborns delivered by CS: arterial cord blood: pH=7.05-7.39; pCO(2)=5.01-10.60 kPa; pO(2)=1.17-5.94 kPa; venous cord blood: pH=7.10-7.42; pCO(2)=3.88-9.36 kPa; pO(2)=1.98-7.23 kPa. Re-evaluated reference ranges play essential role in monitoring conditions of newborns with spontaneous and caesarean delivery.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Armstrong L, Stenson BJ. Use of umbilical cord blood gas analysis in the assessment of the newborn. Arch Dis Child Fetal Neonatal Ed 2007;92:F430–F434. - PMC - PubMed
    1. Valenzuela P, Guijarro R. The effects of time on pH and gas values in the blood contained in the umbilical cord. Acta Obstet Gynecol Scand 2006;85:1307–1309. - PubMed
    1. Bornstein M, Nunnley L. 1996. Cord blood gasses to determine umbilical artery acid‐base analysis. Morton Hospital and Medical Center, Department of Obstetrics and Gynecology [Obgyn.net Web site]. December 20, 1996. Available at: http://www.obgyn.net/hysterectomy‐alternatives/hysterectomy‐alternatives.... Accessed on September 21, 2009.
    1. Thorp JA, Dildy GA, Yeomans ER, Meyer BA, Parisi VM. Umbilical cord blood gas analysis at delivery. Am J Obstet Gynecol 1996;175:517–522. - PubMed
    1. Fouse B. 2002. Reference range evaluation for cord blood gas parameters. In: Skurup A, editor. Acutecaretestingorg: Radiometer [http://acutecaretesting.org/]. June 2002. Available at: http://acutecaretesting.org/56b94e62‐ad37‐46a1‐a3b4‐46840ad2b20b.W5Doc?t.... Accessed on September 13, 2009.

Publication types