Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;51(6):877-82.
doi: 10.3349/ymj.2010.51.6.877.

Impact of prostate volume on the efficacy of high-power potassium-titanyl-phosphate photoselective vaporization of the prostate: a retrospective, short-term follow-up study on evaluating feasibility and safety

Affiliations

Impact of prostate volume on the efficacy of high-power potassium-titanyl-phosphate photoselective vaporization of the prostate: a retrospective, short-term follow-up study on evaluating feasibility and safety

Ja Hyeon Ku et al. Yonsei Med J. 2010 Nov.

Abstract

Purpose: We determined the impact of prostate volume on the efficacy of the high-power (80 W) potassium-titanyl-phosphate (KTP) photoselective laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS).

Materials and methods: Patients were stratified into 3 groups according to prostate volume: '< 40 g' (n = 49) and '40-59 g' (n = 49) and '≥ 60 g' (n = 22). Median follow-up was 9 months (range 6 to 21).

Results: No differences in age and follow-up duration were observed in the three groups. At baseline, no significant differences were noted in the three groups in terms of the International Prostate Symptom Score (IPSS) (21.4, 19.4 and 19.1; p = 0.412) as well as the maximum flow rate (Qmax) (10.2, 9.2, and 8.6 mL/s; p = 0.291) and post-void residual (PVR) (66.2, 80.4, and 71.5 mL; p = 0.856). The mean operative times were 30.9, 46.9, and 58.6 minutes (p< 0.001) and total median energy deliveries for each group were 62.3, 97.6, and 135.9 kJ, respectively (p< 0.001). No severe intraoperative complication was observed. At the last follow-up, these parameters improved significantly regardless of prostate volume, and the IPSS (11.1, 9.4, and 12.3; p = 0.286) as well as Qmax (15.9, 15.9, and 14.2 mL/s; p = 0.690) and PVR (33.7, 28.4, and 14.2 mL; p = 0.395) were not significantly different among the groups.

Conclusion: Although a larger prostate requires more time and energy delivery, photoselective laser vaporization of the prostate is safe and efficacious for patients with LUTS regardless of prostate volume.

PubMed Disclaimer

Conflict of interest statement

The authors have no financial conflicts of interest.

Similar articles

Cited by

References

    1. Hai MA, Malek RS. Photoselective vaporization of the prostate: initial experience with a new 80 W KTP laser for the treatment of benign prostatic hyperplasia. J Endourol. 2003;17:93–96. - PubMed
    1. Te AE, Malloy TR, Stein BS, Ulchaker JC, Nseyo UO, Hai MA, et al. Photoselective vaporization of the prostate for the treatment of benign prostatic hyperplasia: 12-month results from the first United States multicenter prospective trial. J Urol. 2004;72:1404–1408. - PubMed
    1. Sandhu JS, Ng C, Vanderbrink BA, Egan C, Kaplan SA, Te AE. High-power potassium-titanyl-phosphate photoselective laser vaporization of prostate for treatment of benign prostatic hyperplasia in men with large prostates. Urology. 2004;64:1155–1159. - PubMed
    1. Sulser T, Reich O, Wyler S, Ruszat R, Casella R, Hofstetter A, et al. Photoselective KTP laser vaporization of the prostate: first experiences with 65 procedures. J Endourol. 2004;18:976–981. - PubMed
    1. Sandhu JS, Ng CK, Gonzalez RR, Kaplan SA, Te AE. Photoselective laser vaporization prostatectomy in men receiving anticoagulants. J Endourol. 2005;19:1196–1198. - PubMed