Intra-patient supine-prone colon registration in CT colonography using shape spectrum
- PMID: 20879248
- DOI: 10.1007/978-3-642-15705-9_41
Intra-patient supine-prone colon registration in CT colonography using shape spectrum
Abstract
CT colonography (CTC) is a minimally invasive screening technique for colorectal polyps and colon cancer. Since electronic colon cleansing (ECC) cannot completely remove the presence of pseudo-polyps, most CTC protocols acquire both prone and supine images to improve the visualization of the lumen wall and to reduce false positives. Comparisons between the prone and supine images can be facilitated by computerized registration between the scans. In this paper, we develop a fully automatic method for registering colon surfaces extracted from prone and supine images. The algorithm uses shape spectrum to extract the shape characteristics which are employed as the surface signature to find the correspondent regions between the prone and supine lumen surfaces. Our experimental results demonstrate an accuracy of 12.6 +/- 4.20 mm over 20 datasets. It also shows excellent potential in reducing the false positive when it is used to determine polyps through correspondences between prone and supine images.
Similar articles
-
Deformable registration of supine and prone colons for computed tomographic colonography.J Comput Assist Tomogr. 2009 Nov-Dec;33(6):902-11. doi: 10.1097/RCT.0b013e3181a7e2c1. J Comput Assist Tomogr. 2009. PMID: 19940658
-
Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.Med Phys. 2004 Oct;31(10):2912-23. doi: 10.1118/1.1796171. Med Phys. 2004. PMID: 15543800 Clinical Trial.
-
Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection.Med Phys. 2011 Dec;38(12):6633-42. doi: 10.1118/1.3662918. Med Phys. 2011. PMID: 22149845 Free PMC article.
-
Pearls and Pitfalls of Interpretation in CT Colonography.Can Assoc Radiol J. 2020 May;71(2):140-148. doi: 10.1177/0846537119892881. Epub 2020 Jan 24. Can Assoc Radiol J. 2020. PMID: 32063002 Review.
-
Informatics in radiology: dual-energy electronic cleansing for fecal-tagging CT colonography.Radiographics. 2013 May;33(3):891-912. doi: 10.1148/rg.333125039. Epub 2013 Mar 11. Radiographics. 2013. PMID: 23479680 Free PMC article. Review.
Cited by
-
Corresponding Supine and Prone Colon Visualization Using Eigenfunction Analysis and Fold Modeling.IEEE Trans Vis Comput Graph. 2017 Jan;23(1):751-760. doi: 10.1109/TVCG.2016.2598791. IEEE Trans Vis Comput Graph. 2017. PMID: 27875189 Free PMC article.
-
A Compact Shape Descriptor for Triangular Surface Meshes.Comput Aided Des. 2014 Aug 1;53:62-69. doi: 10.1016/j.cad.2014.03.008. Comput Aided Des. 2014. PMID: 24910467 Free PMC article.
-
Computer-aided detection of exophytic renal lesions on non-contrast CT images.Med Image Anal. 2015 Jan;19(1):15-29. doi: 10.1016/j.media.2014.07.005. Epub 2014 Aug 15. Med Image Anal. 2015. PMID: 25189363 Free PMC article.
-
The influence of biophysical parameters in a biomechanical model of cortical folding patterns.Sci Rep. 2021 Apr 8;11(1):7686. doi: 10.1038/s41598-021-87124-y. Sci Rep. 2021. PMID: 33833302 Free PMC article.
-
Hot Spots Conjecture and Its Application to Modeling Tubular Structures.Mach Learn Med Imaging. 2011 Sep;7009:225-232. doi: 10.1007/978-3-642-24319-6_28. Mach Learn Med Imaging. 2011. PMID: 27796012 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources