Anteroposterior positioning of the tibial component and its effect on the mechanics of patellofemoral contact
- PMID: 20884990
- DOI: 10.1302/0301-620X.92B10.24221
Anteroposterior positioning of the tibial component and its effect on the mechanics of patellofemoral contact
Abstract
The biomechanics of the patellofemoral joint can become disturbed during total knee replacement by alterations induced by the position and shape of the different prosthetic components. The role of the patella and femoral trochlea has been well studied. We have examined the effect of anterior or posterior positioning of the tibial component on the mechanisms of patellofemoral contact in total knee replacement. The hypothesis was that placing the tibial component more posteriorly would reduce patellofemoral contact stress while providing a more efficient lever arm during extension of the knee. We studied five different positions of the tibial component using a six degrees of freedom dynamic knee simulator system based on the Oxford rig, while simulating an active knee squat under physiological loading conditions. The patellofemoral contact force decreased at a mean of 2.2% for every millimetre of posterior translation of the tibial component. Anterior positions of the tibial component were associated with elevation of the patellofemoral joint pressure, which was particularly marked in flexion > 90°. From our results we believe that more posterior positioning of the tibial component in total knee replacement would be beneficial to the patellofemoral joint.
Similar articles
-
Upsizing the femoral component increases patellofemoral contact force in total knee replacement.J Bone Joint Surg Br. 2012 Jan;94(1):56-61. doi: 10.1302/0301-620X.94B1.27514. J Bone Joint Surg Br. 2012. PMID: 22219248
-
The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacement.J Bone Joint Surg Br. 2007 Mar;89(3):408-12. doi: 10.1302/0301-620X.89B3.18276. J Bone Joint Surg Br. 2007. PMID: 17356162
-
Is there a biomechanical explanation for anterior knee pain in patients with patella alta?: influence of patellar height on patellofemoral contact force, contact area and contact pressure.J Bone Joint Surg Br. 2009 Mar;91(3):344-50. doi: 10.1302/0301-620X.91B3.21592. J Bone Joint Surg Br. 2009. PMID: 19258610
-
Biomechanics of medial unicondylar in combination with patellofemoral knee arthroplasty.Knee. 2014;21 Suppl 1:S3-9. doi: 10.1016/S0968-0160(14)50002-6. Knee. 2014. PMID: 25382365 Review.
-
Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty.Acta Orthop Belg. 2012 Feb;78(1):11-29. Acta Orthop Belg. 2012. PMID: 22523923 Review.
Cited by
-
Musculoskeletal Multibody Simulation Analysis on the Impact of Patellar Component Design and Positioning on Joint Dynamics after Unconstrained Total Knee Arthroplasty.Materials (Basel). 2020 May 21;13(10):2365. doi: 10.3390/ma13102365. Materials (Basel). 2020. PMID: 32455672 Free PMC article.
-
Knee kinetics and kinematics: What are the effects of TKA malconfigurations?Knee Surg Sports Traumatol Arthrosc. 2016 Aug;24(8):2415-21. doi: 10.1007/s00167-015-3514-y. Epub 2015 Jan 24. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 25616363
-
Meniscus Injury Induces Patellofemoral Osteoarthritis Development Mediated by Synovitis and Gait Kinematics: A Preclinical Study.Cartilage. 2024 Nov 20:19476035241299769. doi: 10.1177/19476035241299769. Online ahead of print. Cartilage. 2024. PMID: 39567862 Free PMC article.
-
Do refinements to original designs improve outcome of total knee replacement? A retrospective cohort study.J Orthop Surg Res. 2014 Feb 6;9:7. doi: 10.1186/1749-799X-9-7. J Orthop Surg Res. 2014. PMID: 24502700 Free PMC article.
-
How to read a postoperative knee replacement radiograph.Skeletal Radiol. 2012 May;41(5):493-501. doi: 10.1007/s00256-011-1297-x. Epub 2011 Oct 16. Skeletal Radiol. 2012. PMID: 22002099 Review.
MeSH terms
LinkOut - more resources
Full Text Sources