The CyScope® fluorescence microscope, a reliable tool for tuberculosis diagnosis in resource-limited settings
- PMID: 20889889
- PMCID: PMC2946766
- DOI: 10.4269/ajtmh.2010.10-0153
The CyScope® fluorescence microscope, a reliable tool for tuberculosis diagnosis in resource-limited settings
Abstract
Poor laboratory equipment and few human resources have made it difficult to implement microscopic diagnosis of pulmonary tuberculosis (TB) on a large scale basis worldwide. Three hundred sputum samples from patients in Cameroon were studied by using the CyScope®, a new light-emitting, diode-based, fluorescence microscope, to compare auramine-rhodamine fluorescence with the conventional Ziehl-Neelsen staining method. Five fluorescence protocols were tested to reduce manipulation time. Smear positivity for acid-fast bacilli with the Ziehl-Neelsen staining method was 27.7% (83 of 300) compared with 33.3% (100 of 300) with the fluorescent method. Staining time with the modified fluorescence protocol could be reduced from 21 minutes to 10 minutes. This study confirmed that the fluorescence staining method is more sensitive than the Ziehl-Neelsen staining method. It is suggested that the training of laboratory technicians on fluorescence microscopy should be scaled up for increased disease control.
Similar articles
-
Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum as proficient alternative tool in the diagnosis of pulmonary tuberculosis in countries with limited resource settings.Int J Mycobacteriol. 2023 Apr-Jun;12(2):144-150. doi: 10.4103/ijmy.ijmy_13_23. Int J Mycobacteriol. 2023. PMID: 37338475
-
Light-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.Int J Tuberc Lung Dis. 2012;16(3):402-7. doi: 10.5588/ijtld.10.0762. Int J Tuberc Lung Dis. 2012. PMID: 22640455
-
Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum.Clin Infect Dis. 2008 Jul 15;47(2):203-7. doi: 10.1086/589248. Clin Infect Dis. 2008. PMID: 18532893
-
The future looks bright: low-cost fluorescent microscopes for detection of Mycobacterium tuberculosis and Coccidiae.Trans R Soc Trop Med Hyg. 2008 Jun;102(6):520-1. doi: 10.1016/j.trstmh.2008.02.020. Epub 2008 Apr 10. Trans R Soc Trop Med Hyg. 2008. PMID: 18405928 Review.
-
Smear microscopy as a diagnostic tool of tuberculosis: Review of smear negative cases, frequency, risk factors, and prevention criteria.Indian J Tuberc. 2018 Jul;65(3):190-194. doi: 10.1016/j.ijtb.2018.02.001. Epub 2018 Feb 13. Indian J Tuberc. 2018. PMID: 29933859 Review.
Cited by
-
Comparison of LED and conventional fluorescence microscopy for detection of acid fast bacilli in a low-incidence setting.PLoS One. 2011;6(7):e22495. doi: 10.1371/journal.pone.0022495. Epub 2011 Jul 21. PLoS One. 2011. PMID: 21811622 Free PMC article.
-
Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda.BMC Infect Dis. 2016 Nov 8;16(1):660. doi: 10.1186/s12879-016-2009-x. BMC Infect Dis. 2016. PMID: 27825314 Free PMC article.
-
Optimising Mycobacterium tuberculosis detection in resource limited settings.BMJ Open. 2014 Mar 3;4(3):e004093. doi: 10.1136/bmjopen-2013-004093. BMJ Open. 2014. PMID: 24589822 Free PMC article.
-
Staining with two observational methods for the diagnosis of tuberculous meningitis.Exp Ther Med. 2016 Dec;12(6):3934-3940. doi: 10.3892/etm.2016.3859. Epub 2016 Nov 2. Exp Ther Med. 2016. PMID: 28105125 Free PMC article.
References
-
- World Health Organization . Global Tuberculosis Control: Epidemiology, Strategy, Financing: WHO Report 2009. Geneva: World Health Organization, WHO.HTM/TB/2009.411; 2009.
-
- Sohn H, Minion J, Albert H, Dheda K, Pai M. TB diagnostic tests: how do we figure out their costs? Expert Rev Anti Infect Ther. 2009;7:723–733. - PubMed
-
- Getahun H, Harrington M, O'Brien R, Nunn P. Diagnosis of smear-negative pulmonary tuberculosis in people with HIV infection or AIDS in resource-constrained settings: informing urgent policy changes. Lancet. 2007;369:2042–2049. - PubMed
-
- Göhde W. A Fluorescence-Based Rapid Malaria Test for Resource-Constrained Areas. Clinical Laboratory International. 2008;32((5)) http://dev.cli-online.com/feature-articles/clinical-laboratory-articles/... Available at. Accessed July 30, 2010.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical