Effects on the surrounding tissues and morphological changes of components after implantation of PMMA and heparin surface modified PMMA intraocular lens in rabbit eyes
- PMID: 2092164
- DOI: 10.3341/kjo.1990.4.2.73
Effects on the surrounding tissues and morphological changes of components after implantation of PMMA and heparin surface modified PMMA intraocular lens in rabbit eyes
Abstract
The aim of this study was to evaluate the cellular response and morphological changes of cells on the intraocular lens(IOL) implanted over a course of time and to identify the basic mechanism of IOL adaptation to tissue reaction in the implanted eye by comparing polymethylmethacrylate (PMMA) IOL with heparin surface modified PMMA IOL. ECCE using Healon was done in 36 eyes of 36 rabbits. A heparin surface modified IOL was implanted in 18 eyes (Group I), while PMMA IOL was implanted into another 18 eyes (Group II). Corneal thickness and endothelial cell density were measured for 3 months. Postoperatively, the eyes were enucleated, and a cytopathologic examination of the cells on the surface of the IOL and their ultrastructural changes were observed with light and scanning microscope at various points of time. The findings of this present study suggested that heparin surface modified PMMA IOL reduced the degree of endothelial cell damage, postoperative tissue reaction, and pigment deposits on the surface of the IOL. These were statistically significant. The most important cell was considered to be the macrophage for the adaptation of IOL in the eye which gradually changed into a fibroblast-like cell, giant cell and finally disappeared after forming an acellular membrane on the IOL.
Similar articles
-
Ocular growth in newborn rabbit eyes implanted with a poly(methyl methacrylate) or silicone intraocular lens.J Cataract Refract Surg. 1997;23 Suppl 1:629-34. doi: 10.1016/s0886-3350(97)80045-4. J Cataract Refract Surg. 1997. PMID: 9278816
-
[Heparin-surface-modified PMMA intraocular lenses in children in early and late follow-up].Klin Oczna. 2003;105(5):273-6. Klin Oczna. 2003. PMID: 14746178 Polish.
-
Fibrinous reaction on implanted intraocular lenses. A comparison of conventional PMMA and heparin surface modified lenses.J Cataract Refract Surg. 1992 May;18(3):236-9. doi: 10.1016/s0886-3350(13)80899-1. J Cataract Refract Surg. 1992. PMID: 1593429
-
Clinicopathologic findings after experimental implantation of synthetic intraocular lenses in dogs.Am J Vet Res. 1993 Apr;54(4):616-21. Am J Vet Res. 1993. PMID: 8484584
-
Comparison of the postoperative inflammatory response in the normal eye with heparin-surface-modified and poly(methyl methacrylate) intraocular lenses.J Cataract Refract Surg. 1995 Sep;21(5):579-85. doi: 10.1016/s0886-3350(13)80221-0. J Cataract Refract Surg. 1995. PMID: 7473124 Clinical Trial.
Cited by
-
The Inflammatory and Foreign Body Reaction of Polymethyl Methacrylate Glaucoma Drainage Device in the Rabbit Eye.Transl Vis Sci Technol. 2020 Feb 18;9(3):20. doi: 10.1167/tvst.9.3.20. Transl Vis Sci Technol. 2020. PMID: 32714646 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical