Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
- PMID: 20922522
- DOI: 10.1007/s00259-010-1603-1
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
Abstract
Purpose: The combination of positron emission tomography (PET) and magnetic resonance (MR) tomography in a single device is anticipated to be the next step following PET/CT for future molecular imaging application. Compared to CT, the main advantages of MR are versatile soft tissue contrast and its capability to acquire functional information without ionizing radiation. However, MR is not capable of measuring a physical quantity that would allow a direct derivation of the attenuation values for high-energy photons.
Methods: To overcome this problem, we propose a fully automated approach that uses a dedicated T1-weighted MR sequence in combination with a customized image processing technique to derive attenuation maps for whole-body PET. The algorithm automatically identifies the outer contour of the body and the lungs using region-growing techniques in combination with an intensity analysis for automatic threshold estimation. No user interaction is required to generate the attenuation map.
Results: The accuracy of the proposed MR-based attenuation correction (AC) approach was evaluated in a clinical study using whole-body PET/CT and MR images of the same patients (n = 15). The segmentation of the body and lung contour (L-R directions) was evaluated via a four-point scale in comparison to the original MR image (mean values >3.8). PET images were reconstructed using elastically registered MR-based and CT-based (segmented and non-segmented) attenuation maps. The MR-based AC showed similar behaviour as CT-based AC and similar accuracy as offered by segmented CT-based AC. Standardized uptake value (SUV) comparisons with reference to CT-based AC using predefined attenuation coefficients showed the largest difference for bone lesions (mean value ± standard variation of SUV(max): -3.0% ± 3.9% for MR; -6.5% ± 4.1% for segmented CT). A blind comparison of PET images corrected with segmented MR-based, CT-based and segmented CT-based AC afforded identical lesion detectability, but slight differences in image quality were found.
Conclusion: Our MR-based attenuation correction method offers similar correction accuracy as offered by segmented CT. According to the specialists involved in the blind study, these differences do not affect the diagnostic value of the PET images.
Similar articles
-
Preclinical evaluation of MR attenuation correction versus CT attenuation correction on a sequential whole-body MR/PET scanner.Invest Radiol. 2013 May;48(5):313-22. doi: 10.1097/RLI.0b013e31827a49ba. Invest Radiol. 2013. PMID: 23296082 Free PMC article.
-
Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.Invest Radiol. 2016 Jan;51(1):66-71. doi: 10.1097/RLI.0000000000000208. Invest Radiol. 2016. PMID: 26348596
-
Performance of whole-body integrated 18F-FDG PET/MR in comparison to PET/CT for evaluation of malignant bone lesions.J Nucl Med. 2014 Feb;55(2):191-7. doi: 10.2967/jnumed.113.123646. Epub 2013 Dec 5. J Nucl Med. 2014. PMID: 24309383
-
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.Eur J Nucl Med Mol Imaging. 2009 Mar;36 Suppl 1:S93-104. doi: 10.1007/s00259-008-1007-7. Eur J Nucl Med Mol Imaging. 2009. PMID: 19104810 Review.
-
Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction.Invest Radiol. 2016 Oct;51(10):624-34. doi: 10.1097/RLI.0000000000000289. Invest Radiol. 2016. PMID: 27175550 Review.
Cited by
-
Quantitative simultaneous positron emission tomography and magnetic resonance imaging.J Med Imaging (Bellingham). 2014 Oct;1(3):033502. doi: 10.1117/1.JMI.1.3.033502. Epub 2014 Nov 3. J Med Imaging (Bellingham). 2014. PMID: 26158055 Free PMC article.
-
Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting.MAGMA. 2013 Feb;26(1):159-71. doi: 10.1007/s10334-012-0347-2. Epub 2012 Oct 9. MAGMA. 2013. PMID: 23053713 Review.
-
Emerging role of MRI in radiation therapy.J Magn Reson Imaging. 2018 Dec;48(6):1468-1478. doi: 10.1002/jmri.26271. Epub 2018 Sep 8. J Magn Reson Imaging. 2018. PMID: 30194794 Free PMC article. Review.
-
MLAA-based attenuation correction of flexible hardware components in hybrid PET/MR imaging.EJNMMI Phys. 2017 Dec;4(1):12. doi: 10.1186/s40658-017-0177-4. Epub 2017 Mar 1. EJNMMI Phys. 2017. PMID: 28251575 Free PMC article.
-
Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET.J Am Med Inform Assoc. 2013 Nov-Dec;20(6):1037-45. doi: 10.1136/amiajnl-2012-001544. Epub 2013 Jun 12. J Am Med Inform Assoc. 2013. PMID: 23761683 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical