Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Feb;37(2):135-42.
doi: 10.1002/uog.7767. Epub 2011 Jan 12.

Fetal umbilical artery Doppler to predict compromise of fetal/neonatal wellbeing in a high-risk population: systematic review and bivariate meta-analysis

Affiliations
Free article
Meta-Analysis

Fetal umbilical artery Doppler to predict compromise of fetal/neonatal wellbeing in a high-risk population: systematic review and bivariate meta-analysis

R K Morris et al. Ultrasound Obstet Gynecol. 2011 Feb.
Free article

Abstract

Objective: We investigated the accuracy of fetal umbilical artery Doppler to predict the risk of compromise of fetal/neonatal wellbeing in a high-risk population.

Methods: Searches in MEDLINE, Embase, The Cochrane Library and Medion (from inception to March 2009) were carried out, together with hand searching of relevant journals, reference list checking of included articles and contact with experts. Criteria for selection were observational studies with umbilical artery Doppler used in a high-risk pregnant population with an outcome measure for compromise of fetal/neonatal wellbeing. Data on study design, quality and results were extracted to construct 2 × 2 tables. Bivariate meta-analysis was performed. Likelihood ratios (LRs) were used as the summary measure of accuracy.

Results: One-hundred and four studies met the selection criteria (19 191 fetuses). In a high-risk population, umbilical artery Doppler predicted small-for-gestational age with a pooled LR+ of 3.76 (2.96, 4.76) and pooled LR- of 0.52 (0.45, 0.61), and compromise of fetal/neonatal wellbeing with a pooled LR+ of 3.41 (2.68, 4.34) and pooled LR- of 0.55 (0.48, 0.62). In this group it was also possible to predict, with accuracy, intrauterine death (pooled LR+ = 4.37 (0.88, 21.8); pooled LR- = 0.25 (0.07, 0.91)) and acidosis (pooled LR+ = 2.75 (1.48, 5.11); pooled LR- = 0.58 (0.36, 0.94)).

Conclusions: In a high-risk population, fetal umbilical artery Doppler is a moderately useful test with which to predict mortality and risk of compromise.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources