Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jan;25(1):57-65.
doi: 10.1038/eye.2010.139. Epub 2010 Oct 8.

Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma

Affiliations

Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma

A Garas et al. Eye (Lond). 2011 Jan.

Abstract

Purpose: To evaluate the diagnostic accuracy of retinal nerve fibre layer thickness (RNFLT), ganglion cell complex (GCC), and optic disc measurements made with the RTVue-100 Fourier-domain optical coherence tomography (OCT) to detect glaucoma in a Caucasian referral population.

Methods: One randomly selected eye of 286 Caucasian patients (93 healthy, 36 ocular hypertensive, 46 preperimetric glaucoma, and 111 perimetric glaucoma eyes) was evaluated.

Results: Using the software-provided classification, for the total population sensitivity did not exceed 73.6% for the optic nerve head parameters, and 62.7% for the other parameters. Specificity was high (94.6-100%) for most RNFLT and GCC parameters, but low (72.0-76.3%) for the optic disc parameters. Positive predictive value varied between 98.1 and 100% for the main RNFLT parameters, 92.6 and 100% for the 16 RNFLT sectors, 92.4 and 99.0% for the GCC parameters, but did not exceed 86.3% for any of the optic disc parameters. Positive likelihood ratio (PLR) was higher than 10 for average, inferior and superior RNFLT (25.5 to infinite), 12 of the 16 RNFLT sectors (12.6 to infinite), and three of the four GCC parameters (40.0 to 48.6). No optic disc parameter had a PLR higher than 3.0.

Conclusions: RNFLT and GCC parameters of the RTVue-100 Fourier-domain OCT showed moderate sensitive but high specificity, positive predictive value and PLR for detection of glaucoma. The optic disc parameters had lower diagnostic accuracy than the RNFLT and GCC parameters.

PubMed Disclaimer

References

    1. González-García AO, Vizzeri G, Bowd C, Medeiros FA, Zangwill LM, Weinreb RN. Reproducibility of RTVue retinal nerve fibre layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol. 2009;147:1067–1074. - PMC - PubMed
    1. Garas A, Vargha P, Holló G. Reproducibility of retinal nerve fibre layer and macular thickness measurement with the RTVue-100 optical coherence tomograph. Ophthalmology. 2010;117:738–746. - PubMed
    1. Garas A, Tóth M, Vargha P, Holló G. Comparison of repeatability of retinal nerve fibre layer thickness measurement made using the RTVue Fourier-domain optical coherence tomograph and the GDx scanning laser polarimeter with variable or enhanced corneal compensation. J Glaucoma. 2010;19 (6:412–417. - PubMed
    1. Garas A, Vargha P, Holló G.Automatic, operator-adjusted, and manual disc definition for optic nerve head and retinal nerve fibre layer measurements with the RTVue-100 optical coherence tomograph J Glaucoma 2010. E-pub ahead of print 29 April 2010, doi:10.1097/IJG.0b013e3181d787fd - DOI - PubMed
    1. Moreno-Montañés J, Olmo N, Alvarez A, García N, Zarranz-Ventura J. Cirrus high-definition optical coherence tomography compared with Stratus optical coherence tomography in glaucoma diagnosis. Invest Ophthalmol Vis Sci. 2010;51:335–343. - PubMed

Publication types