Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Dec;35(4):436-42.
doi: 10.1016/j.jaut.2010.09.005. Epub 2010 Oct 6.

PBC screen: an IgG/IgA dual isotype ELISA detecting multiple mitochondrial and nuclear autoantibodies specific for primary biliary cirrhosis

Affiliations
Comparative Study

PBC screen: an IgG/IgA dual isotype ELISA detecting multiple mitochondrial and nuclear autoantibodies specific for primary biliary cirrhosis

Haiying Liu et al. J Autoimmun. 2010 Dec.

Abstract

A dual isotype (IgG, IgA) enzyme-linked immunosorbent assay (ELISA) designed to provide enhanced detection of primary biliary cirrhosis (PBC)-specific autoantibodies against both major mitochondrial and nuclear antigens has been developed and recently become commercially available. The assay (PBC Screen) simultaneously detects IgG and IgA autoantibodies to the immunodominant portions of the 3 major mitochondrial (MIT3) and nuclear (gp210, and sp100) antigens. The aim of this study was to compare the performance of the PBC Screen to the combined performance obtained with individual IgG ELISAs to MIT3, gp210, and sp100 on a large group of selected patients from multiple centers. A total of 1175 patients with PBC and 1232 subjects without PBC were evaluated. Non-PBC groups included healthy controls (624) as well as individuals with autoimmune hepatitis (281), primary sclerosing cholangitis (77), viral hepatitis (91 hepatitis B and 98 hepatitis C), other liver diseases (31), and other infectious or autoimmune diseases (30). The PBC Screen at the receiver operator characteristic optimized cutoff of 27.8 units, had an overall sensitivity of 83.8%, specificity of 94.7% and area under curve of 0.9212. This was similar to the specificity of 96.1% obtained by the combined results of individual MIT3, sp100, and gp210 IgG ELISAs (kappa index at 0.898). Of the 253 PBC patients without AMA detectable by immunofluorescence, 113 (44.7%) were interpreted as positive for PBC-specific autoantibodies. In conclusion, the PBC Screen is an appropriate first-line test for the diagnosis of PBC, including for patients negative for markers assessed using conventional methods.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources