Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Jan;258(1):134-45.
doi: 10.1148/radiol.10092373. Epub 2010 Oct 8.

Intracranial aneurysms in patients with subarachnoid hemorrhage: CT angiography as a primary examination tool for diagnosis--systematic review and meta-analysis

Affiliations
Meta-Analysis

Intracranial aneurysms in patients with subarachnoid hemorrhage: CT angiography as a primary examination tool for diagnosis--systematic review and meta-analysis

Henriëtte E Westerlaan et al. Radiology. 2011 Jan.

Erratum in

  • Radiology. 2011 Aug;260(2):612. van Dijk, M J [corrected to van Dijk, J M C]

Abstract

Purpose: To calculate the sensitivity and specificity of computed tomographic (CT) angiography in the diagnosis of cerebral aneurysms in patients with acute subarachnoid hemorrhage (SAH) at presentation.

Materials and methods: A systematic search for relevant studies was performed of the PubMed/MEDLINE and EMBASE databases. Two reviewers independently assessed the methodologic quality of each study by using the Quality Assessment of Diagnostic Accuracy Studies tool. The inclusion criteria were met by 50 studies. Heterogeneity was tested, and the presence of publication bias was visually assessed (by using a funnel plot). A meta-analysis of the reported sensitivity and specificity of each study with 95% confidence intervals (CIs) was performed on a per-patient level.

Results: Concerning sensitivity, the selected studies showed moderate heterogeneity. For specificity, low heterogeneity was observed. Moderate-heterogeneity studies that investigated only sensitivity or specificity were excluded from the pooled analyses by using a bivariate random effects model. The majority of the studies (n = 30) used a four-detector row CT scanner. The studies had good methodologic quality. Pooled sensitivity was 98% (95% CI: 97%, 99%), and pooled specificity was 100% (95% CI: 97%, 100%). Potential sources of variability among the studies were variations in the methodologic features (quality score), CT examination procedure (number of rows on the multidetector CT scanner), the standard of reference used, and the prevalence of ruptured intracranial aneurysms. There was evidence for publication bias, which may have led to overestimation of the diagnostic accuracy of CT angiography.

Conclusion: Multidetector CT angiography can be used as a primary examination tool in the diagnostic work-up of patients with SAH.

PubMed Disclaimer

Comment in

Similar articles

Cited by

MeSH terms