Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Feb;46(2):106-15.
doi: 10.1097/RLI.0b013e3181f44184.

Indeterminate focal liver lesions incidentally discovered at gray-scale US: role of contrast-enhanced sonography

Affiliations

Indeterminate focal liver lesions incidentally discovered at gray-scale US: role of contrast-enhanced sonography

Tommaso Vincenzo Bartolotta et al. Invest Radiol. 2011 Feb.

Abstract

Objectives: to assess the role of contrast-enhanced ultrasound (CEUS) in the characterization of focal liver lesions (FLLs) incidentally discovered but indeterminate at gray-scale ultrasound (US).

Materials and methods: one hundred forty-two consecutive patients with 174 FLLs (169 benign and 5 malignant) incidentally discovered but indeterminate at gray-scale US, underwent CEUS after the administration of SonoVue. Two readers independently reviewed CEUS scans and: (1) classified each lesion as malignant or benign on a 5-point scale of confidence by means of definite diagnostic criteria; (2) provided if possible a specific diagnosis; (3) were requested if further imaging was needed for lesion characterization. Sensitivity, specificity, and areas under the receiver-operating characteristic curve (Az) as well as interobserver agreement were calculated.

Results: at CEUS, both readers correctly differentiated benign from malignant lesions in 168 of 174 (96.5%) cases (P < 0.0001). A specific correct diagnosis was provided in 123 of 174 (70.7%) and 127 of 174 (72.9%) cases for reader 1 and 2, respectively (P < 0.0001). A further imaging study to characterize the lesion after CEUS was requested in 67 cases (38.5%) for reader 1 (P < 0.001) and 46 cases (26.4%) for reader 2 (P < 0.001). Receiver-operating characteristic analysis after CEUS revealed Az value of 1 for both readers and sensitivity and specificity values of 100% and 97.04% for reader 1 and 100% and 96.45 for reader 2 respectively (P < 0.0001). Inter-reader agreement at CEUS was good (weighted k = 0.779).

Conclusion: CEUS improves the diagnostic performance of radiologists in the characterization of indeterminate FLLs incidentally discovered at US and reduces the need for further radiologic work-up.

PubMed Disclaimer

LinkOut - more resources