Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;24(11):3112-22.
doi: 10.1519/JSC.0b013e3181f0a8d5.

Physiological determinants of the candidate physical ability test in firefighters

Affiliations

Physiological determinants of the candidate physical ability test in firefighters

Andrew K Sheaff et al. J Strength Cond Res. 2010 Nov.

Abstract

The purpose of this study was to examine the relative importance of physiological characteristics during firefighting performance, as assessed by the Candidate Physical Ability Test (CPAT). Subjects included career and volunteer firefighters aged 18-39 (N = 33). Upper- and lower-body strength, muscle endurance, lower body muscle power, body composition analysis, aerobic capacity, anaerobic fitness, and the heart rate (HR) and blood pressure response to stair climbing were assessed to determine the physiological characteristics of the subjects. To quantify firefighting performance, the CPAT was administered by members of the fire service. Absolute and relative mean power during the Wingate anaerobic cycling test (WAnT), relative peak power during the WAnT, and absolute maximal oxygen uptake (VO2max) were significantly higher in those who passed the CPAT (N = 18), compared to those who failed (N = 15; p < 0.01). Mean power during the WAnT, fatigue index during WAnT, absolute VO2max, upper body strength, grip strength, and the HR response to stair climbing were significantly related to CPAT performance time (p < 0.01). Absolute VO2max and anaerobic fatigue resistance during WAnT best predicted CPAT performance (Adj. R2 = 0.817; p < 0.001). Performance on the ceiling breach and pull was the only CPAT task that was not significantly related to the physiological characteristics assessed. Measures of anaerobic and cardiovascular fitness best predict overall CPAT performance, and individual task performance. Remedial programs aimed at improving firefighting performance should target anaerobic and aerobic fitness qualities.

PubMed Disclaimer

Publication types

LinkOut - more resources