Spectral control of an alexandrite laser for an airborne water-vapor differential absorption lidar system
- PMID: 20941182
- DOI: 10.1364/AO.33.006439
Spectral control of an alexandrite laser for an airborne water-vapor differential absorption lidar system
Abstract
A narrow-linewidth pulsed alexandrite laser has been greatly modified for improved spectral stability in an aircraft environment, and its operation has been evaluated in the laboratory for making water-vapor differential absorption lidar measurements. An alignment technique is described to achieve the optimum free spectral range ratio for the two étalons inserted in the alexandrite laser cavity, and the sensitivity of this ratio is analyzed. This technique drastically decreases the occurrence of mode hopping, which is commonly observed in a tunable, two-intracavity-étalon laser system. High spectral purity (> 99.85%) at 730 nm is demonstrated by the use of a water-vapor absorption line as a notch filter. The effective cross sections of 760-nm oxygen and 730-nm water-vapor absorption lines are measured at different pressures by usingthis laser, which has a finite linewidth of 0.02 cm(-1) (FWHM). It is found that for water-vapor absorption linewidths greater than 0.04 cm(-1) (HWHM), or for altitudes below 10 km, the laser line can be considered monochromatic because the measured effective absorption cross section is within 1% of the calculated monochromatic cross section. An analysis of the environmental sensitivity of the two intracavity étalons is presented, and a closed-loop computer control for active stabilization of the two intracavity étalons in the alexandrite laser is described. Using a water-vapor absorption line as a wavelength reference, we measure a long-term frequency drift (≈ 1.5 h) of less than 0.7 pm in the laboratory.
Similar articles
-
Airborne differential absorption lidar system for measurements of atmospheric water vapor and aerosols.Appl Opt. 1994 Sep 20;33(27):6422-38. doi: 10.1364/AO.33.006422. Appl Opt. 1994. PMID: 20941181
-
Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser.Appl Opt. 1993 Feb 20;32(6):992-8. doi: 10.1364/AO.32.000992. Appl Opt. 1993. PMID: 20802779
-
Double-pulse dual-wavelength alexandrite laser for atmospheric water vapor measurement.Appl Opt. 1991 Sep 20;30(27):3930-7. doi: 10.1364/AO.30.003930. Appl Opt. 1991. PMID: 20706484
-
Injection-seeded pulsed alexandrite laser for differential absorption lidar application.Appl Opt. 1994 Jun 20;33(18):3941-50. doi: 10.1364/AO.33.003941. Appl Opt. 1994. PMID: 20935740
-
Intrapulse temporal and wavelength shifts of a high-power 2.1-µm Ho:YAG laser and their potential influence on atmospheric lidar measurements.Appl Opt. 1994 Nov 20;33(33):7747-53. doi: 10.1364/AO.33.007747. Appl Opt. 1994. PMID: 20962985