Design and operation of microelectrochemical gates and integrated circuits
- PMID: 20942419
- DOI: 10.1021/ja107095z
Design and operation of microelectrochemical gates and integrated circuits
Abstract
Here we report a simple design philosophy, based on the principles of bipolar electrochemistry, for the operation of microelectrochemical integrated circuits. The inputs for these systems are simple voltage sources, but because they do not require much power they could be activated by chemical or biological reactions. Device output is an optical signal arising from electrogenerated chemiluminescence. Individual microelectrochemical logic gates are described first, and then multiple logic circuits are integrated into a single microfluidic channel to yield an integrated circuit that can perform parallel logic functions. AND, OR, NOR, and NAND gates are described. Eventually, systems such as those described here could provide on-chip data processing functions for lab-on-a-chip devices.
Similar articles
-
Microelectrochemical logic circuits.J Am Chem Soc. 2003 Aug 20;125(33):9934-5. doi: 10.1021/ja0366585. J Am Chem Soc. 2003. PMID: 12914451
-
Modular multi-level circuits from immobilized DNA-based logic gates.J Am Chem Soc. 2007 Dec 5;129(48):14875-9. doi: 10.1021/ja0710149. Epub 2007 Nov 10. J Am Chem Soc. 2007. PMID: 17994734
-
Surface-confined assemblies and polymers for molecular logic.Acc Chem Res. 2011 Aug 16;44(8):563-73. doi: 10.1021/ar200002v. Epub 2011 Jun 16. Acc Chem Res. 2011. PMID: 21678901
-
Integrated electrochemical DNA biosensors for lab-on-a-chip devices.Electrophoresis. 2009 Oct;30(19):3386-97. doi: 10.1002/elps.200900319. Electrophoresis. 2009. PMID: 19802851 Review.
-
Electron spin for classical information processing: a brief survey of spin-based logic devices, gates and circuits.Nanotechnology. 2009 Oct 14;20(41):412001. doi: 10.1088/0957-4484/20/41/412001. Epub 2009 Sep 16. Nanotechnology. 2009. PMID: 19755729 Review.
Cited by
-
Biocomputing for Portable, Resettable, and Quantitative Point-of-Care Diagnostics: Making the Glucose Meter a Logic-Gate Responsive Device for Measuring Many Clinically Relevant Targets.Angew Chem Int Ed Engl. 2018 Jul 26;57(31):9702-9706. doi: 10.1002/anie.201804292. Epub 2018 Jul 9. Angew Chem Int Ed Engl. 2018. PMID: 29893502 Free PMC article.
-
Decoding Network Structure in On-Chip Integrated Flow Cells with Synchronization of Electrochemical Oscillators.Sci Rep. 2017 Apr 7;7:46027. doi: 10.1038/srep46027. Sci Rep. 2017. PMID: 28387237 Free PMC article.
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous