Maximum diameter measurements of aortic aneurysms on axial CT images after endovascular aneurysm repair: sufficient for follow-up?
- PMID: 20945067
- DOI: 10.1007/s00270-010-9992-x
Maximum diameter measurements of aortic aneurysms on axial CT images after endovascular aneurysm repair: sufficient for follow-up?
Abstract
Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard.
Materials and methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard.
Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001).
Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.
Similar articles
-
Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms.Acta Radiol. 2011 Apr 1;52(3):317-23. doi: 10.1258/ar.2010.100229. Acta Radiol. 2011. PMID: 21498369
-
Influence of computed tomography angiography reconstruction software on anatomic measurements and endograft component selection for endovascular abdominal aortic aneurysm repair.J Vasc Surg. 2014 May;59(5):1224-31.e1-3. doi: 10.1016/j.jvs.2013.11.003. Epub 2014 Jan 16. J Vasc Surg. 2014. PMID: 24439321
-
Preoperative planning for endovascular aortic repair of abdominal aortic aneurysms: feasibility of nonenhanced MR angiography versus contrast-enhanced CT angiography.Radiology. 2013 Jun;267(3):948-55. doi: 10.1148/radiol.13121557. Epub 2013 Feb 7. Radiology. 2013. PMID: 23392427
-
Abdominal aortic aneurysms revisited: MDCT with multiplanar reconstructions for identifying indicators of instability in the pre- and postoperative patient.Radiographics. 2015 Jan-Feb;35(1):254-68. doi: 10.1148/rg.351130137. Radiographics. 2015. PMID: 25590402 Review.
-
Computed tomography scanning for endograft planning: evolving toward three-dimensional, single source imaging.Semin Vasc Surg. 2004 Jun;17(2):126-34. doi: 10.1053/j.semvascsurg.2004.03.007. Semin Vasc Surg. 2004. PMID: 15185178 Review.
Cited by
-
Evaluation the Aortic Aneurysm Remodeling After a Successful Stentgraft Implantation.Pol J Radiol. 2016 Oct 13;81:486-490. doi: 10.12659/PJR.900116. eCollection 2016. Pol J Radiol. 2016. PMID: 27800038 Free PMC article.
-
Comparability of semiautomatic tortuosity measurements in the carotid artery.Neuroradiology. 2019 Feb;61(2):147-153. doi: 10.1007/s00234-018-2112-3. Epub 2018 Oct 18. Neuroradiology. 2019. PMID: 30338348 Free PMC article.
-
Late intervention for type II endoleak is not determined by early sac diameter or volume changes after EVAR.Radiol Oncol. 2024 Nov 28;58(4):573-579. doi: 10.2478/raon-2024-0056. eCollection 2024 Dec 1. Radiol Oncol. 2024. PMID: 39608008 Free PMC article.
-
On growth measurements of abdominal aortic aneurysms using maximally inscribed spheres.Med Eng Phys. 2015 Jul;37(7):683-91. doi: 10.1016/j.medengphy.2015.04.011. Epub 2015 May 23. Med Eng Phys. 2015. PMID: 26004506 Free PMC article.