Hemodynamics and outcomes of aortic valve replacement with a 17- or 19-mm valve
- PMID: 20947599
- DOI: 10.1177/0218492310381174
Hemodynamics and outcomes of aortic valve replacement with a 17- or 19-mm valve
Abstract
When aortic valve replacement is performed in patients with a small aortic annulus, prosthesis-patient mismatch is of concern because it may affect postoperative clinical status. We conducted a retrospective study of outcomes in 65 patients with aortic stenosis requiring valve replacement. Fifty were given a 17-mm or 19-mm St. Jude Regent mechanical valve, and 15 were given a 19-mm Medtronic Mosaic bioprosthesis. Echocardiography was carried out preoperatively, at discharge, and at follow-up. There was 1 (2%) operative death in the Regent group and none in the Mosaic group. There was no valve-related event. Follow-up echocardiography in both groups revealed a significant increase in the mean effective orifice area index, a decrease in the mean left ventricular-aortic pressure gradient, and a decrease in the mean left ventricular mass index. Prosthesis-patient mismatch (effective orifice area index <0.85 cm(2) · m(-2)) existed in 13 (26%) patients in the Regent group and 11 (73%) in the Mosaic group at discharge. All patients improved to New York Heart Association functional class II or better. A small-sized prosthesis may provide satisfactory clinical and hemodynamic results in patients with a small aortic annulus.
Similar articles
-
The 17-mm St. Jude Medical Regent valve is a valid option for patients with a small aortic annulus.Ann Thorac Surg. 2009 Jan;87(1):90-4. doi: 10.1016/j.athoracsur.2008.09.051. Ann Thorac Surg. 2009. PMID: 19101276
-
Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences.Interact Cardiovasc Thorac Surg. 2011 Dec;13(6):606-10. doi: 10.1510/icvts.2011.283218. Epub 2011 Sep 4. Interact Cardiovasc Thorac Surg. 2011. PMID: 21891800
-
Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.J Thorac Cardiovasc Surg. 2014 Dec;148(6):2854-60. doi: 10.1016/j.jtcvs.2014.07.049. Epub 2014 Aug 1. J Thorac Cardiovasc Surg. 2014. PMID: 25218544 Clinical Trial.
-
Aortic Stenosis and Small Aortic Annulus.Circulation. 2019 Jun 4;139(23):2685-2702. doi: 10.1161/CIRCULATIONAHA.118.038408. Epub 2019 Jun 3. Circulation. 2019. PMID: 31157994 Review.
-
Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement?Interact Cardiovasc Thorac Surg. 2009 Sep;9(3):510-8. doi: 10.1510/icvts.2009.207597. Epub 2009 Jun 4. Interact Cardiovasc Thorac Surg. 2009. PMID: 19497953 Review.
Cited by
-
Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve.Indian J Thorac Cardiovasc Surg. 2023 May 20;39(5):1-9. doi: 10.1007/s12055-023-01520-9. Online ahead of print. Indian J Thorac Cardiovasc Surg. 2023. PMID: 37359507 Free PMC article.
-
Patient-prosthesis mismatch in patients with aortic valve replacement.Gen Thorac Cardiovasc Surg. 2013 May;61(5):274-9. doi: 10.1007/s11748-013-0216-6. Epub 2013 Feb 13. Gen Thorac Cardiovasc Surg. 2013. PMID: 23404312 Free PMC article.
-
Prognostic impact of small size sutureless prostheses: results for 241 patients from an international registry.J Cardiothorac Surg. 2025 Jul 25;20(1):313. doi: 10.1186/s13019-025-03558-9. J Cardiothorac Surg. 2025. PMID: 40713846 Free PMC article.
-
Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?J Cardiothorac Surg. 2014 Jan 17;9:17. doi: 10.1186/1749-8090-9-17. J Cardiothorac Surg. 2014. PMID: 24438101 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources