Recent advances in pulse oximetry

Recent advances in pulse oximetry

Maxime Cannesson et al. F1000 Med Rep. .

Abstract

Conventional pulse oximetry uses two wavelengths of light (red and infrared) transmitted through a finger and a photodetector to analyze arterial hemoglobin oxygen saturation and pulse rate. Recent advances in pulse oximetry include: extended analysis of the photo plethysmographic waveform; use of multiple wavelengths of light to quantify methemoglobin, carboxyhemoglobin and total hemoglobin content in blood; and use of electronic processes to improve pulse oximeter signal processing during conditions of low signal-to-noise ratio. These advances have opened new clinical applications for pulse oximeters that will have an impact on patient monitoring and management.

PubMed Disclaimer

References

    1. Shelley KH, Murray WB, Chang D. Arterial-pulse oximetry loops: a new method of monitoring vascular tone. J Clin Monit. 1997;13:223–8. doi: 10.1023/A:1007361020825. - DOI - PubMed
    1. Landsverk SA, Hoiseth LO, Kvandal P, Hisdal J, Skare O, Kirkeboen KA. Poor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients. Anesthesiology. 2008;109:849–55. doi: 10.1097/ALN.0b013e3181895f9f. - DOI - PubMed
    1. Hummler HD, Engelmann A, Pohlandt F, Högel J, Franz AR. Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value? Intensive Care Med. 2006;32:1428–31. doi: 10.1007/s00134-006-0254-y. - DOI - PubMed
    1. Mowafi HA, Ismail SA, Shafi MA, Al-Ghandi AA. The efficacy of perfusion index as an indicator for intravascular injection of epinephrine-containing epidural test dose in propofol-anesthetized adults. Anesth Analg. 2009;108:549–53. doi: 10.1213/ane.0b013e31818fc35b. - DOI - PubMed
    2. Changes Clinical Practice

      F1000 Factor 3.0 Recommended

      Evaluated by Pekka Talke 03 Mar 2009

    1. Mowafi HA, Arab SA, Ismail SA, Al-Ghamdi AA, Al-Metwalli RR. Plethysmographic pulse wave amplitude is an effective indicator for intravascular injection of epinephrine-containing epdirual test in sevoflurane-anesthetized pediatric patients. Anesth Analg. 2008;2008:1536–41. - PubMed
    2. F1000 Factor 3.0 Recommended

      Evaluated by Francis Veyckemans 04 Aug 2008