Patient selection and activity planning guide for selective internal radiotherapy with yttrium-90 resin microspheres

Affiliations

Patient selection and activity planning guide for selective internal radiotherapy with yttrium-90 resin microspheres

Wan-Yee Lau et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: Selective internal radiotherapy (SIRT) with yttrium-90 ((90)Y) resin microspheres can improve the clinical outcomes for selected patients with inoperable liver cancer. This technique involves intra-arterial delivery of β-emitting microspheres into hepatocellular carcinomas or liver metastases while sparing uninvolved structures. Its unique mode of action, including both (90)Y brachytherapy and embolization of neoplastic microvasculature, necessitates activity planning methods specific to SIRT.

Methods and materials: A panel of clinicians experienced in (90)Y resin microsphere SIRT was convened to integrate clinical experience with the published data to propose an activity planning pathway for radioembolization.

Results: Accurate planning is essential to minimize potentially fatal sequelae such as radiation-induced liver disease while delivering tumoricidal (90)Y activity. Planning methods have included empiric dosing according to degree of tumor involvement, empiric dosing adjusted for the body surface area, and partition model calculations using Medical Internal Radiation Dose principles. It has been recommended that at least two of these methods be compared when calculating the microsphere activity for each patient.

Conclusions: Many factors inform (90)Y resin microsphere SIRT activity planning, including the therapeutic intent, tissue and vasculature imaging, tumor and uninvolved liver characteristics, previous therapies, and localization of the microsphere infusion. The influence of each of these factors has been discussed.