Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?
- PMID: 20953855
- PMCID: PMC3094625
- DOI: 10.1007/s11999-010-1605-0
Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?
Abstract
Background: Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages.
Questions/purposes: We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size.
Methods: We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size.
Results: One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size.
Conclusions: Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.
Figures
Similar articles
-
Large diameter head metal-on-metal bearings total hip arthroplasty: preliminary results.Orthop Traumatol Surg Res. 2010 Feb;96(1):14-20. doi: 10.1016/j.rcot.2009.12.006. Orthop Traumatol Surg Res. 2010. PMID: 20170852
-
Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?Clin Orthop Relat Res. 2017 May;475(5):1349-1355. doi: 10.1007/s11999-016-4966-1. Clin Orthop Relat Res. 2017. PMID: 27385222 Free PMC article.
-
No Difference in Dislocation Rates Comparing Large Diameter Jumbo Femoral Heads and Dual-Mobility Bearings in Revision Total Hip Arthroplasty.J Arthroplasty. 2021 Nov;36(11):3716-3721. doi: 10.1016/j.arth.2021.07.008. Epub 2021 Jul 29. J Arthroplasty. 2021. PMID: 34391597
-
Femoral head diameter considerations for primary total hip arthroplasty.Orthop Traumatol Surg Res. 2015 Feb;101(1 Suppl):S25-9. doi: 10.1016/j.otsr.2014.07.026. Epub 2015 Jan 14. Orthop Traumatol Surg Res. 2015. PMID: 25596984 Review.
-
Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.Clin Orthop Relat Res. 2016 Apr;474(4):1072-6. doi: 10.1007/s11999-015-4381-z. Epub 2015 Jun 19. Clin Orthop Relat Res. 2016. PMID: 26088765 Free PMC article. Review.
Cited by
-
[Larger heads compensate for an increased risk of THA dislocation in high-risk patients].Orthopade. 2015 May;44(5):381-91. doi: 10.1007/s00132-015-3093-0. Orthopade. 2015. PMID: 25869176 German.
-
Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.Int Orthop. 2017 Mar;41(3):661-668. doi: 10.1007/s00264-016-3383-0. Epub 2017 Jan 14. Int Orthop. 2017. PMID: 28091768 Review.
-
In-vivo hip arthrokinematics during supine clinical exams: Application to the study of femoroacetabular impingement.J Biomech. 2015 Aug 20;48(11):2879-86. doi: 10.1016/j.jbiomech.2015.04.022. Epub 2015 Apr 22. J Biomech. 2015. PMID: 25997726 Free PMC article.
-
Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.Clin Orthop Relat Res. 2012 Feb;470(2):382-7. doi: 10.1007/s11999-011-2161-y. Clin Orthop Relat Res. 2012. PMID: 22045071 Free PMC article.
-
Few adverse reactions to metal on metal articulation in total hip arthroplasty in a review study on 358 consecutive cases with 1 to 5 years follow-up.Open Orthop J. 2012;6:366-70. doi: 10.2174/1874325001206010366. Epub 2012 Aug 24. Open Orthop J. 2012. PMID: 22930667 Free PMC article.
References
-
- Bartz RL, Noble PC, Kadakia NR, Tullos HS. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am. 2000;82:1300–1307. - PubMed
-
- Berend KR, Lombardi AV., Jr Total hip arthroplasty via the less invasive direct lateral abductor splitting approach. Semin Arthroplasty. 2004;15:87–93. doi: 10.1053/j.sart.2004.08.004. - DOI
-
- Berry DJ, Knoch M, Schleck CD, Harmsen WS. The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am. 2004;86:9–14. - PubMed
Publication types