Comparative Study
. 2011 Jun;469(6):1547-53.
doi: 10.1007/s11999-010-1605-0.

Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Affiliations
Comparative Study

Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Adolph V Lombardi Jr et al. Clin Orthop Relat Res. 2011 Jun.

Abstract

Background: Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages.

Questions/purposes: We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size.

Methods: We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size.

Results: One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size.

Conclusions: Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Distribution of femoral head reconstruction accuracy is shown; that is, the difference between the size of the implanted femoral head and the native femoral head.

Similar articles

Cited by

References

    1. Bartz RL, Noble PC, Kadakia NR, Tullos HS. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am. 2000;82:1300–1307. - PubMed
    1. Berend KR, Lombardi AV., Jr Total hip arthroplasty via the less invasive direct lateral abductor splitting approach. Semin Arthroplasty. 2004;15:87–93. doi: 10.1053/j.sart.2004.08.004. - DOI
    1. Berry DJ, Knoch M, Schleck CD, Harmsen WS. The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am. 2004;86:9–14. - PubMed
    1. Berry DJ, Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2456–2463. doi: 10.2106/JBJS.D.02860. - DOI - PubMed
    1. Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty. 2007;22:125–129. doi: 10.1016/j.arth.2007.03.009. - DOI - PubMed

Publication types

MeSH terms