Real-time potentiometric detection of bacteria in complex samples
- PMID: 20961052
- DOI: 10.1021/ac101739b
Real-time potentiometric detection of bacteria in complex samples
Abstract
Detecting and identifying pathogen bacteria is essential to ensure quality at all stages of the food chain and to diagnose and control microbial infections. Traditional detection methods, including those based on cell culturing, are tedious and time-consuming, and their further application in real samples generally implies more complex pretreatment steps. Even though state-of-the-art techniques for detecting microorganisms enable the quantification of very low concentrations of bacteria, to date it has been difficult to obtain successful results in real samples in a simple, reliable, and rapid manner. In this Article, we demonstrate that the label-free detection and identification of living bacteria in real samples can be carried out in a couple of minutes and in a direct, simple, and selective way at concentration levels as low as 6 colony forming units/mL (CFU) in complex matrices such as milk or 26 CFU/mL in apple juice where the pretreatment step of samples is extremely easy. We chose Escherichia coli ( E. coli ) CECT 675 cells as a model organism as a nonpathogenic surrogate for pathogenic E. coli O157:H7 to test the effectiveness of a potentiometric aptamer-based biosensor. This biosensor uses single-walled carbon nanotubes (SWCNT) as excellent ion-to-electron transducers and covalently immobilized aptamers as biorecognition elements. The selective aptamer-target interaction significantly changes the electrical potential, thus allowing for both interspecies and interstrain selectivity and enabling the direct detection of the target. This technique is therefore a powerful tool for the immediate identification and detection of microorganisms. We demonstrate the highly selective detection of living bacteria with an immediate linear response of up to 10(4) CFU/mL. The biosensor can be easily built and used, is regenerated without difficulty, and can be used at least five times with no loss in the minimum amount of detected bacteria.
Similar articles
-
Solid-contact potentiometric aptasensor based on aptamer functionalized carbon nanotubes for the direct determination of proteins.Analyst. 2010 May;135(5):1037-41. doi: 10.1039/b926958d. Epub 2010 Feb 8. Analyst. 2010. PMID: 20419254
-
Carbon nanotube-based aptasensors for the rapid and ultrasensitive detection of bacteria.Methods. 2013 Oct;63(3):233-8. doi: 10.1016/j.ymeth.2013.07.008. Epub 2013 Jul 17. Methods. 2013. PMID: 23872060
-
Carbon nanotubes-based chemiresistive biosensors for detection of microorganisms.Biosens Bioelectron. 2010 Dec 15;26(4):1437-41. doi: 10.1016/j.bios.2010.07.077. Epub 2010 Jul 30. Biosens Bioelectron. 2010. PMID: 20729063
-
Detection of microorganisms using biosensors-a smarter way towards detection techniques.Biosens Bioelectron. 2009 Dec 15;25(4):661-7. doi: 10.1016/j.bios.2009.08.037. Epub 2009 Aug 31. Biosens Bioelectron. 2009. PMID: 19782558 Review.
-
Application of Aptamer-Based Biosensor for Rapid Detection of Pathogenic Escherichia coli.Sensors (Basel). 2018 Aug 1;18(8):2518. doi: 10.3390/s18082518. Sensors (Basel). 2018. PMID: 30071682 Free PMC article. Review.
Cited by
-
Single-Stranded DNA Aptamers against Pathogens and Toxins: Identification and Biosensing Applications.Biomed Res Int. 2015;2015:419318. doi: 10.1155/2015/419318. Epub 2015 Jun 23. Biomed Res Int. 2015. PMID: 26199940 Free PMC article. Review.
-
Isolation of an Aptamer that Binds Specifically to E. coli.PLoS One. 2016 Apr 22;11(4):e0153637. doi: 10.1371/journal.pone.0153637. eCollection 2016. PLoS One. 2016. PMID: 27104834 Free PMC article.
-
Advances in Aptamer-Based Biosensors and Cell-Internalizing SELEX Technology for Diagnostic and Therapeutic Application.Biosensors (Basel). 2022 Oct 25;12(11):922. doi: 10.3390/bios12110922. Biosensors (Basel). 2022. PMID: 36354431 Free PMC article. Review.
-
Multiplexed aptasensing of food contaminants by using terminal deoxynucleotidyl transferase-produced primer-triggered rolling circle amplification: application to the colorimetric determination of enrofloxacin, lead (II), Escherichia coli O157:H7 and tropomyosin.Mikrochim Acta. 2019 Nov 25;186(12):840. doi: 10.1007/s00604-019-3935-2. Mikrochim Acta. 2019. PMID: 31768650
-
Aptamer-based analysis: a promising alternative for food safety control.Sensors (Basel). 2013 Nov 28;13(12):16292-311. doi: 10.3390/s131216292. Sensors (Basel). 2013. PMID: 24287543 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources