Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Oct;3(10):1022-31.
doi: 10.1016/j.jcin.2010.07.013.

Transradial approach for coronary angiography and interventions: results of the first international transradial practice survey

Affiliations
Free article

Transradial approach for coronary angiography and interventions: results of the first international transradial practice survey

Olivier F Bertrand et al. JACC Cardiovasc Interv. 2010 Oct.
Free article

Abstract

Objectives: The aim of this study was to evaluate practice of transradial approach (TRA).

Background: TRA has been adopted as an alternative access site for coronary procedures.

Methods: A questionnaire was distributed worldwide with Internet-based software.

Results: The survey was conducted from August 2009 to January 2010 among 1,107 interventional cardiologists in 75 countries. Although pre-TRA dual hand circulation testing is not uniform in the world, >85% in the U.S. perform Allen or oximetry testing. Right radial artery is used in almost 90%. Judkins catheters are the most popular for left coronary artery angiographies (66.5%) and right coronary artery angiographies (58.8%). For percutaneous coronary intervention (PCI), 6-F is now standard. For PCI of left coronary artery, operators use standard extra back-up guiding catheters in >65% and, for right coronary artery 70.4% use right Judkins catheters. Although heparin remains the routine antithrombotic agent in the world, bivalirudin is frequently used in the U.S. for PCI. The incidence of radial artery occlusion before hospital discharge is not assessed in >50%. Overall, approximately 50% responded that their TRA practice will increase in the future (68.4% in the U.S.).

Conclusions: TRA is already widely used across the world. Diagnostic and guiding-catheters used for TRA remain similar to those used for traditional femoral approach, suggesting that specialized radial catheters are not frequently used. However, there is substantial variation in practice as it relates to specific aspects of TRA, suggesting that more data are needed to determine the optimal strategy to facilitate TRA and optimize radial artery patency after catheterization.

PubMed Disclaimer

Comment in

  • Transradial catheterization's grass roots epidemic.
    Gilchrist IC. Gilchrist IC. JACC Cardiovasc Interv. 2010 Oct;3(10):1032-4. doi: 10.1016/j.jcin.2010.08.009. JACC Cardiovasc Interv. 2010. PMID: 20965461 No abstract available.
  • Facilitating radial conversion.
    Feld S. Feld S. JACC Cardiovasc Interv. 2011 Apr;4(4):468; author reply 468-9. doi: 10.1016/j.jcin.2011.01.007. JACC Cardiovasc Interv. 2011. PMID: 21511229 No abstract available.

MeSH terms

Substances

LinkOut - more resources