Reproducibility of mean transit time for maximal myocardial flow assessment by videodensitometry

Affiliations

Reproducibility of mean transit time for maximal myocardial flow assessment by videodensitometry

N H Pijls et al. Int J Card Imaging. 1990.

Abstract

In the assessment of myocardial perfusion by ECG-triggered digital radiography, time parameters are calculated from the time density curve (TDC) and related to blood flow. Recently we developed a method which uses mean transit time (Tmn) as time parameter, and which is in accordance with the original principles of indicator dilution theory. In this approach, variability in vascular volume is excluded and Tmn-1, determined at maximal hyperemia, showed an excellent correlation with maximal flow in animal validation studies. For calculation of Tmn, however, a large part of the descending limb of the TDC has to be known for reliable extrapolation, and especially this part of the curve is subject to variability in image quality in man. Therefore we tested reproducibility of Tmn in 30 arteries in 20 patients. Tmn was derived from the TDCs, obtained from paired studies under identical circumstances with an interval of 10 minutes. Satisfactory images could be obtained in all but one patient. Image processing was performed in an identical way in the paired studies. Reproducibility proved to be excellent for all three coronary arteries. The absolute value of the relative differences between the first and second determination was 7 +/- 7% for the LAD, 6 +/- 3% for LCx and 4 +/- 2% for the RCA (mean +/- SD). Correlation coefficients between both measurements were 0.97, 0.95 and 0.95 for the respective arteries. Therefore, it is concluded that, using this approach, Tmn at maximal hyperemia can be determined reproducibly in man and used for maximal myocardial flow assessment.

PubMed Disclaimer

References

    1. Circulation. 1990 Apr;81(4):1331-40 - PubMed
    1. Am J Cardiol. 1985 Jan 1;55(1):188-93 - PubMed
    1. Am J Roentgenol Radium Ther Nucl Med. 1970 May;109(1):21-4 - PubMed
    1. Int J Card Imaging. 1990;5(2-3):191-202 - PubMed
    1. Circulation. 1967 Dec;36(6):951-63 - PubMed