Angiographic morphology of recurrent stenoses after percutaneous transluminal coronary angioplasty: are lesions longer at restenosis?
- PMID: 2097307
- DOI: 10.1007/BF02398889
Angiographic morphology of recurrent stenoses after percutaneous transluminal coronary angioplasty: are lesions longer at restenosis?
Abstract
Angiographic morphology was analysed in 32 patients who developed restenosis after initially successful coronary angioplasty. The mean minimal luminal diameter of the dilated coronary segments increased from 0.9 mm to 2.3 mm after dilatation, but decreased to 0.9 mm at restenosis. The reference diameter was unchanged after dilatation and at restenosis. Mean stenosis length before the initial angioplasty was 7.0 mm but at the repeat procedure had increased to 8.7 mm (mean increase 1.7 mm, 95% confidence interval 0.6 to 2.8 mm, p less than 0.01). There were no significant differences in mean trans-stenotic pressure gradient and mean eccentricity ratio between the initial and repeat angioplasty procedures. In individual patients the changes in stenosis morphology were unpredictable, but overall stenoses tended to be longer at restenosis. In some patients stenosis length increased by several millimetres but the success rate of repeat angioplasty was high and the clinical importance of the changes in stenosis morphology are uncertain.
Similar articles
-
Morphologic changes during follow-up after successful percutaneous transluminal coronary balloon angioplasty: quantitative angiographic analysis in 778 lesions--further evidence for the restenosis paradox. MERCATOR Study Group (Multicenter European Research trial with Cilazapril after Angioplasty to prevent Transluminal Coronary Obstruction and Restenosis).Am Heart J. 1994 Mar;127(3):483-94. doi: 10.1016/0002-8703(94)90654-8. Am Heart J. 1994. PMID: 8122593 Clinical Trial.
-
Restenosis rate after multiple percutaneous transluminal coronary angioplasty procedures at the same site. A quantitative angiographic study in consecutive patients undergoing a third angioplasty procedure for a second restenosis.Circulation. 1993 Sep;88(3):969-74. doi: 10.1161/01.cir.88.3.969. Circulation. 1993. PMID: 8353924
-
Influence of balloon size and stenosis morphology on immediate and delayed elastic recoil after percutaneous transluminal coronary angioplasty.J Am Coll Cardiol. 1991 Aug;18(2):506-11. doi: 10.1016/0735-1097(91)90607-b. J Am Coll Cardiol. 1991. PMID: 1856419
-
[Balloon angioplasty of stent restenosis: early and late results of first and second PTCA in focal and diffuse stenosis].Z Kardiol. 1998;87 Suppl 3:65-71; discussion 79-80. doi: 10.1007/s003920050541. Z Kardiol. 1998. PMID: 9791913 Review. German.
-
Coronary restenosis after optimal (stent-like) initial angiographic results obtained by traditional balloon angioplasty.G Ital Cardiol. 1997 Jul;27(7):645-53. G Ital Cardiol. 1997. PMID: 9282284 Review.