On the role of arbitration of discordant double readings of screening mammography: experience from two Italian programmes
- PMID: 20981500
- DOI: 10.1007/s11547-010-0606-0
On the role of arbitration of discordant double readings of screening mammography: experience from two Italian programmes
Abstract
Purpose: The authors sought to assess the role of arbitration by a third reader of discordant double readings to reduce the rate of recalls to diagnostic assessment.
Materials and methods: A consecutive series of 7,660 double readings of screening examinations were considered. Discordant recalls were arbitrated by an expert reader (negative/positive). Diagnostic assessment was performed irrespective of arbitration results, and its outcome was used as reference standard for the study purpose. Assuming that negative arbitration would deny recall, its impact was assessed in terms of reduced recall rate and reduced cancer detection rate. Cost analysis of introducing arbitration was performed according to these results.
Results: Recalls at double reading were 528 (6.8%), of which 230 (43.5%) were concordant and 298 (56.5%) were discordant. The latter underwent arbitration, which was negative in 216 (72.4%) and positive in 82 (27.6%) cases, respectively. Overall, 49 cancers were detected (6.39 ‰ screened, 9.2% recalled): 43 cancers were detected among concordant (5.6 ‰ screened, 18.6% concordant) and six among discordant recalls (0.7 ‰ screened, 2.0% discordant). Six cancers were observed among arbitrated cases: five (6%) in positive and one (4.6 ‰) in negative arbitrations. Negative arbitration would have spared 216 assessment procedures (2.8% absolute, 40.9% relative reduction of recall rate) while missing one cancer case (0.13 ‰ absolute, 2.0% relative reduction of cancer detection rate). Arbitration cost was 74 euro, whereas 216 spared assessment procedures would have cost 14,558.4-23,346 euro.
Conclusions: Arbitration is a cost-effective procedure that could be employed as a first measure to counterbalance excess recall rate observed in a double-reading scenario.
Similar articles
-
The role of arbitration of discordant reports at double reading of screening mammograms.J Med Screen. 2005;12(3):125-7. doi: 10.1258/0969141054855337. J Med Screen. 2005. PMID: 16156942
-
Arbitration of discrepant BI-RADS 0 recalls by a third reader at screening mammography lowers recall rate but not the cancer detection rate and sensitivity at blinded and non-blinded double reading.Breast. 2015 Oct;24(5):601-7. doi: 10.1016/j.breast.2015.06.004. Breast. 2015. PMID: 26117723
-
Does computer-aided detection have a role in the arbitration of discordant double-reading opinions in a breast-screening programme?Clin Radiol. 2009 Jan;64(1):46-51. doi: 10.1016/j.crad.2008.07.008. Epub 2008 Sep 4. Clin Radiol. 2009. PMID: 19070697
-
Evaluation of the effect of double reporting on test accuracy in screening and diagnostic imaging studies: A review of the evidence.J Med Imaging Radiat Oncol. 2016 Jun;60(3):306-14. doi: 10.1111/1754-9485.12450. Epub 2016 Mar 21. J Med Imaging Radiat Oncol. 2016. PMID: 26996634 Review.
-
Review of the evidence on the use of arbitration or consensus within breast screening: A systematic scoping review.Radiography (Lond). 2017 May;23(2):171-176. doi: 10.1016/j.radi.2017.01.002. Epub 2017 Feb 13. Radiography (Lond). 2017. PMID: 28390551
Cited by
-
Service and clinical impacts of reader bias in breast cancer screening: a retrospective study.Br J Radiol. 2024 Jan 23;97(1153):120-125. doi: 10.1093/bjr/tqad024. Br J Radiol. 2024. PMID: 38263824 Free PMC article.
-
Discrepant screening mammography assessments at blinded and non-blinded double reading: impact of arbitration by a third reader on screening outcome.Eur Radiol. 2015 Oct;25(10):2821-9. doi: 10.1007/s00330-015-3711-6. Epub 2015 Apr 18. Eur Radiol. 2015. PMID: 25894007
-
Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography.Eur Radiol. 2019 Jan;29(1):337-344. doi: 10.1007/s00330-018-5586-9. Epub 2018 Jun 25. Eur Radiol. 2019. PMID: 29943181
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical