Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;32(5):1228-37.
doi: 10.1002/jmri.22369.

Faster dynamic imaging of speech with field inhomogeneity corrected spiral fast low angle shot (FLASH) at 3 T

Affiliations

Faster dynamic imaging of speech with field inhomogeneity corrected spiral fast low angle shot (FLASH) at 3 T

Bradley P Sutton et al. J Magn Reson Imaging. 2010 Nov.

Abstract

Purpose: To evaluate the impact of magnetic field inhomogeneity correction on achievable imaging speeds for magnetic resonance imaging (MRI) of articulating oropharyngeal structures during speech and to determine if sufficient acquisition speed is available for visualizing speech structures with real-time MRI.

Materials and methods: We designed a spiral fast low angle shot (FLASH) sequence that combines several acquisition techniques with an advanced image reconstruction approach that includes magnetic field inhomogeneity correction. A simulation study was performed to examine the interaction between imaging speed, image quality, number of spiral shots, and field inhomogeneity correction. Six volunteer subjects were scanned to demonstrate adequate visualization of articulating structures during simple speech samples.

Results: The simulation study confirmed that magnetic field inhomogeneity correction improves the available tradeoff between image quality and speed. Our optimized sequence co-acquires magnetic field maps for image correction and achieves a dynamic imaging rate of 21.4 frames per second, significantly faster than previous studies. Improved visualization of anatomical structures, such as the soft palate, was also seen from the field-corrected reconstructions in data acquired on volunteer subjects producing simple speech samples.

Conclusion: Adequate temporal resolution of articulating oropharyngeal structures during speech can be obtained by combining outer volume suppression, multishot spiral imaging, and magnetic field corrected image reconstruction. Correcting for the large, dynamic magnetic field variation in the oropharyngeal cavity improves image quality and allows for higher temporal resolution.

PubMed Disclaimer

MeSH terms

LinkOut - more resources