Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Dec 27;16(48):14439-46.
doi: 10.1002/chem.201001654.

A photoelectrochemical immunosensor based on Au-doped TiO2 nanotube arrays for the detection of α-synuclein

Affiliations

A photoelectrochemical immunosensor based on Au-doped TiO2 nanotube arrays for the detection of α-synuclein

Yarui An et al. Chemistry. .

Abstract

α-Synuclein (α-SYN) is a very important neuronal protein that is associated with Parkinson's disease. In this paper, we utilized Au-doped TiO(2) nanotube arrays to design a photoelectrochemical immunosensor for the detection of α-SYN. The highly ordered TiO(2) nanotubes were fabricated by using an electrochemical anodization technique on pure Ti foil. After that, a photoelectrochemical deposition method was exploited to modify the resulting nanotubes with Au nanoparticles, which have been demonstrated to facilitate the improvement of photocurrent responses. Moreover, the Au-doped TiO(2) nanotubes formed effective antibody immobilization arrays and immobilized primary antibodies (Ab(1)) with high stability and bioactivity to bind target α-SYN. The enhanced sensitivity was obtained by using {Ab(2)-Au-GOx} bioconjugates, which featured secondary antibody (Ab(2)) and glucose oxidase (GOx) labels linked to Au nanoparticles for signal amplification. The GOx enzyme immobilized on the prepared immunosensor could catalyze glucose in the detection solution to produce H(2)O(2), which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of TiO(2) nanotubes upon irradiation of the other side of the Ti foil and led to a prompt photocurrent. The photocurrents were proportional to the α-SYN concentrations, and the linear range of the developed immunosensor was from 50 pg mL(-1) to 100 ng mL(-1) with a detection limit of 34 pg mL(-1). The proposed method showed high sensitivity, stability, reproducibility, and could become a promising technique for protein detection.

PubMed Disclaimer

Publication types

LinkOut - more resources