Multimedia article. Natural orifice transluminal endoscopic surgery applied to sigmoidectomy in survival animal models: using paired magnetic intra-luminal device
- PMID: 21046162
- DOI: 10.1007/s00464-010-1365-7
Multimedia article. Natural orifice transluminal endoscopic surgery applied to sigmoidectomy in survival animal models: using paired magnetic intra-luminal device
Abstract
Background: The clinical application of natural orifice transluminal endoscopic surgery (NOTES) for sigmoidectomy is associated with several difficulties that need to be overcome before wider clinical application of the procedure. The purpose of this study was to evaluate the technical feasibility and safety of transgastric sigmoidectomy in a survival animal model, as well as to evaluate the safety and usability of a custom paired magnetic intraluminal device, which we developed for the NOTES procedure.
Methods: Survival experiments were conducted on 24-33-kg dogs. After anesthesia, a gastrotomy was created using double-channel endoscope, and peritoneoscopy was performed. The sigmoid colon was retracted laterally using paired magnetic intraluminal device, the mesocolon was dissected, and the branch vessel was sealed. The anvil was placed into the descending colon through anus. A proximal and distal colonic transection was then performed. The circular stapler was passed through the anus and performed end-to-end anastomosis. Afterwards the specimen was removed through gastrotomy, and the gastric incision was closed. Postoperatively, all dogs were recovered and monitored for well-being during convalescence. Reexploration was practiced under anesthesia 2 weeks after surgery for evaluation of intra-abdominal complications, and intra-peritoneal cultures for microorganism.
Results: The mean operative time was 141 (range, 122-157) min. There were no complications or physical evidence of sepsis or bowel obstruction during the observation period. Only one dog exhibited decreased body weight, decreasing to 20.4 kg from 22.4 kg after surgery; all of the other dogs exhibited increased body weight. We observed no evidence of peritonitis, intra-abdominal abscess, bleeding, or organ injury on reexploration conducted on day 14 after surgery.
Conclusions: Transgastric NOTES sigmoidectomy is a safe operation technique as evaluated in a dog model. The paired magnetic intraluminal device that was used in this study was useful to avoid an abdominal incision for retracting the sigmoid colon.
Similar articles
-
Natural orifice translumenal endoscopic surgery (NOTES) applied totally to sigmoidectomy: an original technique with survival in a porcine model.Surg Endosc. 2009 Jan;23(1):24-30. doi: 10.1007/s00464-008-0102-y. Epub 2008 Sep 24. Surg Endosc. 2009. PMID: 18814015
-
Hybrid transvaginal natural orifice transluminal endoscopic surgery of radical sigmoidectomy for sigmoid colon cancer.Surg Oncol. 2019 Sep;30:90-91. doi: 10.1016/j.suronc.2019.05.022. Epub 2019 May 27. Surg Oncol. 2019. PMID: 31500793
-
Multimedia article. Combined sentinel node biopsy and localized sigmoid resection entirely by natural orifice transluminal endoscopic surgery: a new challenge to the old paradigm.Dis Colon Rectum. 2009 Apr;52(4):725. doi: 10.1007/DCR.0b013e31819a69af0. Dis Colon Rectum. 2009. PMID: 19404081
-
Assessing transgastric Natural Orifice Transluminal Endoscopic Surgery prior to clinical implementation.Dan Med J. 2014 Aug;61(8):B4903. Dan Med J. 2014. PMID: 25162448 Review.
-
Advances in laparoscopic colorectal surgery: a review on NOTES and transanal extraction of specimen.Asian J Endosc Surg. 2014 Jan;7(1):11-6. doi: 10.1111/ases.12070. Epub 2013 Oct 24. Asian J Endosc Surg. 2014. PMID: 24165166 Review.
Cited by
-
Natural orifice transluminal endoscopic surgery: new minimally invasive surgery come of age.World J Gastroenterol. 2011 Oct 21;17(39):4382-8. doi: 10.3748/wjg.v17.i39.4382. World J Gastroenterol. 2011. PMID: 22110263 Free PMC article.
-
Endoscopic applications of magnets for the treatment of gastrointestinal diseases.World J Gastrointest Endosc. 2019 Dec 16;11(12):548-560. doi: 10.4253/wjge.v11.i12.548. World J Gastrointest Endosc. 2019. PMID: 31839874 Free PMC article. Review.
-
Optimization of tracheoesophageal fistula model established with T-shaped magnet system based on magnetic compression technique.World J Gastroenterol. 2024 Apr 28;30(16):2272-2280. doi: 10.3748/wjg.v30.i16.2272. World J Gastroenterol. 2024. PMID: 38690021 Free PMC article.
-
Minimally invasive surgery for colorectal cancer: past, present, and future.Int J Surg Oncol. 2011;2011:490917. doi: 10.1155/2011/490917. Epub 2011 Aug 18. Int J Surg Oncol. 2011. PMID: 22312511 Free PMC article.
-
Laparoendoscopic single-site simple nephrectomy using a magnetic anchoring system in a porcine model.Investig Clin Urol. 2016 May;57(3):208-14. doi: 10.4111/icu.2016.57.3.208. Epub 2016 May 3. Investig Clin Urol. 2016. PMID: 27195320 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources