Impedance-based flow cytometry for the measurement of microparticles
- PMID: 21049382
- DOI: 10.1055/s-0030-1267035
Impedance-based flow cytometry for the measurement of microparticles
Abstract
Over the last several years, there has been considerable interest in evaluating the biological relevance of alterations in blood-borne microparticle populations. The most commonly employed technique for the characterization of microparticles is light scatter flow cytometry. However, the enumeration and sizing of submicron particles based on light scattering properties can be problematic. Impedance-based flow cytometry based on the Coulter principle offers a sensitive methodology to characterize microparticles. This review details the rationale for employing impedance-based flow cytometry in the measurement of blood-borne microparticles.
© Thieme Medical Publishers.
Similar articles
-
Submicron-precision particle characterization in microfluidic impedance cytometry with double differential electrodes.Lab Chip. 2021 Aug 7;21(15):2869-2880. doi: 10.1039/d1lc00481f. Epub 2021 Jul 8. Lab Chip. 2021. PMID: 34236057
-
Measurement of platelet microparticles.Methods Mol Biol. 2012;788:127-39. doi: 10.1007/978-1-61779-307-3_10. Methods Mol Biol. 2012. PMID: 22130705
-
Overcoming limitations of microparticle measurement by flow cytometry.Semin Thromb Hemost. 2010 Nov;36(8):807-18. doi: 10.1055/s-0030-1267034. Epub 2010 Nov 3. Semin Thromb Hemost. 2010. PMID: 21049381 Review.
-
Ultraviolet light scattering scanning flow cytometry in the characterization of submicron microparticles.Cytometry A. 2023 Sep;103(9):736-743. doi: 10.1002/cyto.a.24769. Epub 2023 Jun 12. Cytometry A. 2023. PMID: 37306103
-
Utilization of microparticles in next-generation assays for microflow cytometers.Anal Bioanal Chem. 2010 Nov;398(6):2373-82. doi: 10.1007/s00216-010-3848-8. Epub 2010 Jun 8. Anal Bioanal Chem. 2010. PMID: 20526882 Free PMC article. Review.
Cited by
-
Circulating microparticles: square the circle.BMC Cell Biol. 2013 Apr 22;14:23. doi: 10.1186/1471-2121-14-23. BMC Cell Biol. 2013. PMID: 23607880 Free PMC article. Review.
-
Tumor-derived tissue factor-positive microparticles and venous thrombosis in cancer patients.Blood. 2013 Sep 12;122(11):1873-80. doi: 10.1182/blood-2013-04-460139. Epub 2013 Jun 24. Blood. 2013. PMID: 23798713 Free PMC article. Review.
-
Advances in Resistive Pulse Sensors: Devices bridging the void between molecular and microscopic detection.Nano Today. 2011 Oct 1;6(5):531-545. doi: 10.1016/j.nantod.2011.08.012. Nano Today. 2011. PMID: 22034585 Free PMC article.
-
The Methods of Choice for Extracellular Vesicles (EVs) Characterization.Int J Mol Sci. 2017 May 29;18(6):1153. doi: 10.3390/ijms18061153. Int J Mol Sci. 2017. PMID: 28555055 Free PMC article. Review.
-
Predictive indicators in peripheral blood and left atrium blood for left atrial spontaneous echo contrast in atrial fibrillation patients.BMC Cardiovasc Disord. 2024 Sep 11;24(1):484. doi: 10.1186/s12872-024-04162-w. BMC Cardiovasc Disord. 2024. PMID: 39261826 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources