Cell-based screening using high-throughput flow cytometry
- PMID: 21050072
- PMCID: PMC3045571
- DOI: 10.1089/adt.2010.0308
Cell-based screening using high-throughput flow cytometry
Abstract
This review describes the use of high-throughput flow cytometry for performing multiplexed cell-based and bead-based screens. With the many advances in cell-based analysis and screening, flow cytometry has historically been underutilized as a screening tool largely due to the limitations in handling large numbers of samples. However, there has been a resurgence in the use of flow cytometry due to a combination of innovations around instrumentation and a growing need for cell-based and bead-based applications. The HTFC™ Screening System (IntelliCyt Corporation, Albuquerque, NM) is a novel flow cytometry-based screening platform that incorporates a fast sample-loading technology, HyperCyt®, with a two-laser, six-parameter flow cytometer and powerful data analysis capabilities. The system is capable of running multiplexed screening assays at speeds of up to 40 wells per minute, enabling the processing of a 96- and 384-well plates in as little as 3 and 12 min, respectively. Embedded in the system is HyperView®, a data analysis software package that allows rapid identification of hits from multiplexed high-throughput flow cytometry screening campaigns. In addition, the software is incorporated into a server-based data management platform that enables seamless data accessibility and collaboration across multiple sites. High-throughput flow cytometry using the HyperCyt technology has been applied to numerous assay areas and screening campaigns, including efflux transporters, whole cell and receptor binding assays, functional G-protein-coupled receptor screening, in vitro toxicology, and antibody screening.
Figures
References
-
- Feng Y. Mitchison TJ. Bender A. Young DW. Tallarico JA. Multi-parameter phenotypic profiling: using cellular effects to characterize small-molecule compounds. Nat Rev Drug Discov. 2009;8:567–578. - PubMed
-
- Edwards BS. Kuckuck FW. Prossnitz ER. Ransom JT. Sklar LA. HTPS flow cytometry: a novel platform for automated high throughput drug discovery and characterization. J Biomol Screen. 2001;6:83–90. - PubMed
-
- Edwards BS. Young SM. Saunders MJ. Bologa C. Oprea TI. Ye RD. Prossnitz ER. Graves SW. Sklar LA. High-throughput flow cytometry for drug discovery. Expert Opin Drug Discov. 2007;2:685–696. - PubMed
-
- Roman DL. Talbot JN. Roof RA. Sunahara RK. Traynor JR. Neubig RR. Identification of small-molecule inhibitors of RGS4 using a high-throughput flow cytometry protein interaction assay. Mol Pharmacol. 2007;71:169–175. - PubMed
-
- Simons PC. Shi M. Foutz T. Cimino DF. Lewis J. Buranda T. Lim W. Neubig RR. McIntire WE. Garrison J. Prossnitz E. Sklar LA. Ligand–receptor–G-protein molecular assemblies on beads for mechanistic studies and screening by flow cytometry. Mol Pharmacol. 2003;64:1227–1238. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
