Radiochromic film dosimetry: past, present, and future
- PMID: 21050785
- DOI: 10.1016/j.ejmp.2010.10.001
Radiochromic film dosimetry: past, present, and future
Abstract
In radiation therapy, an accurate dose determination and a precise dose delivery to the tumour are directly associated with better treatment outcomes in terms of higher tumour control and lower post radiation therapy complications. Over the years, film dosimetry was developed into a powerful tool for radiotherapy treatment verification and quality assurance. This review summarizes development of GAFCHROMIC™ film models through improvement in their sensitivity and uniformity as two dimensional detectors. The most important characteristics as well as the limitations that can affect the performance of the radiochromic film dosimetry systems have been described. An outline of both clinical and research contemporary applications is given particularly emphasizing new applications like brachytherapy, diagnostic radiology and radiobiological experiments. Review concludes through an overview of future directions in development of this important dosimetric tool revolving around its possible use as a three-dimensional dosimeter and the energy dependence of the film's response.
Copyright © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
New developments in radiochromic film dosimetry.Radiat Prot Dosimetry. 2006;120(1-4):100-6. doi: 10.1093/rpd/nci698. Radiat Prot Dosimetry. 2006. PMID: 16987914 Review.
-
Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.Phys Med Biol. 2007 Jul 21;52(14):4211-25. doi: 10.1088/0031-9155/52/14/013. Epub 2007 Jun 18. Phys Med Biol. 2007. PMID: 17664604
-
Evaluation of a new self-developing instant film for imaging and dosimetry.Radiat Prot Dosimetry. 2006;120(1-4):121-4. doi: 10.1093/rpd/nci551. Epub 2006 Apr 27. Radiat Prot Dosimetry. 2006. PMID: 16644995
-
The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy.Phys Med Biol. 2007 Oct 7;52(19):N449-57. doi: 10.1088/0031-9155/52/19/N03. Epub 2007 Sep 14. Phys Med Biol. 2007. PMID: 17881795
-
Reference radiochromic film dosimetry: Review of technical aspects.Phys Med. 2016 Apr;32(4):541-56. doi: 10.1016/j.ejmp.2016.02.008. Epub 2016 Mar 22. Phys Med. 2016. PMID: 27020097 Review.
Cited by
-
Comparative study on measurements of radiochromic films using portable colorimeters.Sci Rep. 2024 Feb 9;14(1):3384. doi: 10.1038/s41598-024-54017-9. Sci Rep. 2024. PMID: 38336983 Free PMC article.
-
Very High-Energy Electron Therapy Toward Clinical Implementation.Cancers (Basel). 2025 Jan 8;17(2):181. doi: 10.3390/cancers17020181. Cancers (Basel). 2025. PMID: 39857964 Free PMC article. Review.
-
Dosimetry of Continuous Random Motion in High Dose Rate Strontium-90 Plesiotherapy.Vet Radiol Ultrasound. 2025 Jan;66(1):e70004. doi: 10.1111/vru.70004. Vet Radiol Ultrasound. 2025. PMID: 39834101 Free PMC article.
-
3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.Phys Med. 2021 Apr;84:159-167. doi: 10.1016/j.ejmp.2021.04.007. Epub 2021 Apr 23. Phys Med. 2021. PMID: 33901860 Free PMC article.
-
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition.J Vis Exp. 2021 Mar 11;(169):10.3791/61692. doi: 10.3791/61692. J Vis Exp. 2021. PMID: 33779614 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous