Practical implementation of a direct method for coherent diffractive imaging
- PMID: 21051146
- DOI: 10.1016/j.ultramic.2010.10.003
Practical implementation of a direct method for coherent diffractive imaging
Abstract
We experimentally implement a direct, non-iterative method for recovering the complex wave in the exit-surface plane of a coherently illuminated object. The form of illumination is subject to certain conditions. By satisfying these conditions, the complex exit-surface wave is directly recovered from a single far-field intensity pattern, by solving a set of linear equations. These linear equations, whose coefficients depend on the incident illumination, are obtained by analyzing the autocorrelation function of the exit-surface wave. This autocorrelation is constructed by taking the inverse Fourier transform of the diffraction pattern. We introduce a preconditioning step, for the system of linear equations, which improves the robustness of the method to noise. While the present experimental proof of concept has been performed using a visible-light laser, the method is applicable to diffractive imaging using coherent X-ray and electron sources.
Copyright © 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Direct exit-wave reconstruction from a single defocused image.Ultramicroscopy. 2011 Aug-Oct;111(9-10):1455-60. doi: 10.1016/j.ultramic.2011.07.005. Epub 2011 Jul 27. Ultramicroscopy. 2011. PMID: 21930016
-
Mask-assisted deterministic phase-amplitude retrieval from a single far-field intensity diffraction pattern: two experimental proofs of principle using visible light.Ultramicroscopy. 2011 Jun;111(7):782-7. doi: 10.1016/j.ultramic.2011.01.011. Epub 2011 Jan 18. Ultramicroscopy. 2011. PMID: 21664548
-
Coherent diffractive imaging of biological samples at synchrotron and free electron laser facilities.J Biotechnol. 2010 Sep 15;149(4):229-37. doi: 10.1016/j.jbiotec.2010.01.024. Epub 2010 Feb 10. J Biotechnol. 2010. PMID: 20149827 Review.
-
A method for correcting the effect of specimen drift on coherent diffractive imaging.Ultramicroscopy. 2010 Mar;110(4):359-65. doi: 10.1016/j.ultramic.2010.01.014. Epub 2010 Feb 1. Ultramicroscopy. 2010. PMID: 20149537
-
Feasibility of imaging living cells at subnanometer resolutions by ultrafast X-ray diffraction.Q Rev Biophys. 2008 Aug-Nov;41(3-4):181-204. doi: 10.1017/S003358350800471X. Q Rev Biophys. 2008. PMID: 19079804 Review.
Cited by
-
Deterministic Bragg Coherent Diffraction Imaging.Sci Rep. 2017 Apr 25;7(1):1132. doi: 10.1038/s41598-017-01164-x. Sci Rep. 2017. PMID: 28442775 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical