. 2011 Mar;26(2):160-7.
doi: 10.1007/s00380-010-0042-z. Epub 2010 Oct 30.

Novel algorithm for identifying T-wave current density alternans using synthesized 187-channel vector-projected body surface mapping

Affiliations

Novel algorithm for identifying T-wave current density alternans using synthesized 187-channel vector-projected body surface mapping

Kenji Nakai et al. Heart Vessels. 2011 Mar.

Abstract

The noninvasive evaluation of ventricular T-wave alternans (TWA) in patients with lethal ventricular arrhythmias is an important issue. In this study, we propose a novel algorithm to identify T-wave current density alternans (TWCA) using synthesized 187-channel vector-projected body surface mapping (187-ch SAVP-ECG). We recorded 10 min of 187-ch SAVP-ECG using a Mason-Likar lead system in the supine position. A recovery time (RT) dispersion map was obtained by averaging the 187-ch SAVP-ECG. The TWCA value was determined from the relative changes in the averaged current density in the T-wave zone (Tpeak ± 50 ms) for two T-wave types. We registered 20 ECG recordings from normal controls and 11 ECG recordings from nine subjects with long QT syndrome (LQT). We divided LQT syndrome subjects into two groups: group 1 provided 9 ECG recordings without visually apparent TWAs, and group 2 provided 2 ECG recordings with visually apparent TWAs. The QTc interval values in the LQT groups were higher than those in the control (515 ± 60 ms in LQT G-1, 600 ± 27 ms in LQT G-2 vs. 415 ± 19 ms in control, P < 0.001). The RTendc dispersion values among the LQT subjects were higher than those of the control subjects (48 ± 19 ms in LQT G-1, 65 ± 30 ms in LQT G-2 vs. 24 ± 10 ms in control, P < 0.01). The mean TWCA value was significantly higher in the LQT G-2 group with visually apparent TWCAs (0.5 ± 0.2% in control, 2.1 ± 1.2% in LQT G-1, and 32.3 ± 6.9% in LQT G-2). Interestingly, the two-dimensional distribution of TWCA in LQT was inhomogeneous and correlated with the distribution of increased RT dispersion. We conclude that a novel algorithm using 187-ch SAVP-ECG might provide new insights into body surface TWCA.

PubMed Disclaimer

Similar articles

Cited by

  • Improved robust T-wave alternans detectors.
    Meste O, Janusek D, Karczmarewicz S, Przybylski A, Kania M, Maciag A, Maniewski R. Meste O, et al. Med Biol Eng Comput. 2015 Apr;53(4):361-70. doi: 10.1007/s11517-015-1243-5. Epub 2015 Feb 3. Med Biol Eng Comput. 2015. PMID: 25644059
  • Congenital long QT syndrome with compound mutations in the KCNH2 gene.
    Bando S, Soeki T, Matsuura T, Niki T, Ise T, Yamaguchi K, Taketani Y, Iwase T, Yamada H, Wakatsuki T, Akaike M, Aiba T, Shimizu W, Sata M. Bando S, et al. Heart Vessels. 2014 Jul;29(4):554-9. doi: 10.1007/s00380-013-0406-2. Epub 2013 Sep 22. Heart Vessels. 2014. PMID: 24057343

References

    1. Int Heart J. 2008 Mar;49(2):153-64 - PubMed
    1. Circulation. 1977 Apr;55(4):574-7 - PubMed
    1. J Appl Physiol (1985). 2002 Feb;92(2):541-9 - PubMed
    1. Int J Cardiovasc Imaging. 2006 Jun-Aug;22(3-4):573-80 - PubMed
    1. Circulation. 1990 Dec;82(6):2185-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources