Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Mar;21(2):739-45.
doi: 10.1007/s10895-010-0764-4. Epub 2010 Nov 4.

Spectrofluorimetric assessment of metoclopramide hydrochloride using terbium doped in PMMA matrix optical sensor

Affiliations

Spectrofluorimetric assessment of metoclopramide hydrochloride using terbium doped in PMMA matrix optical sensor

M S Attia et al. J Fluoresc. 2011 Mar.

Abstract

A new, simple and accurate spectrofluorimetric method for the determination of metoclopramide hydrochloride was developed. The metoclopramide hydrochloride can remarkably enhance the luminescence intensity of the Tb(3+) ion doped in PMMA matrix at λ(ex)=360 nm in methanol at pH 6.9. The intensity of the emission band at 545 nm of Tb(3+) ion doped in PMMA matrix is increased due to the energy transfer from metoclopramide hydrochloride to Tb(3+) in the excited stated. The effect of different parameters, e.g., pH, temperature, Tb(3+) concentration, foreign ions that control the fluorescence intensity of the produced ion associate was critically investigated. The calibration curve of the emission intensity at 545 nm shows linear response of metoclopramide over a concentration range of 5 × 10(-5)-5.0 × 10(-8) M with detection limit of 8.7 × 10(-10) M. The method was used successfully for the determination of metoclopramide in pharmaceutical preparations and human serum. The average recovery of 99.48% with standard deviation of 0.32% and 96.98% with standard deviation of 0.4%, of pharmaceutical preparations and human serum respectively, were obtained which compared will with the results obtained from standard LC method of average recovery 99.04% and standard deviation of 0.6% and average recovery of 98.19% with standard deviation of 0.6% of pharmaceutical preparations and human serum, respectively.

PubMed Disclaimer

References

    1. J Pharm Biomed Anal. 2003 Mar 10;31(3):515-21 - PubMed
    1. Analyst. 1996 Nov;121(11):1551-6 - PubMed
    1. J Pharm Biomed Anal. 2001 Jun;25(3-4):631-7 - PubMed
    1. J Pharm Biomed Anal. 2005 Jun 1;38(1):14-20 - PubMed
    1. J Pharm Biomed Anal. 2000 Nov;23(6):1045-55 - PubMed

LinkOut - more resources