Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block
- PMID: 21059701
- DOI: 10.1093/bja/aeq306
Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block
Abstract
Background: Previous studies have demonstrated that lower local anaesthetic (LA) volumes can be used for ultrasound (US)-guided interscalene brachial plexus block (ISB). However, no study has examined whether US can reduce the volume required when compared with nerve stimulation (NS) for ISB. Our aim was to do this by comparing the minimum effective analgesic volumes (MEAVs).
Methods: After ethics approval and informed consent, patients undergoing shoulder surgery were recruited to this randomized, double-blind, up-down sequential allocation study. The volume used for both US and NS was dependent upon the success or failure of the previous block. Success was defined as a verbal rating score of 0/10, 30 min after surgery. Ten needle passes were allowed before defaulting to the opposite group. Patients received general anaesthesia. Pain scores and analgesic consumption were assessed by a blinded observer. Statistical comparisons of continuous variables were performed using Student's t-test and Mann-Whitney U-test as appropriate. Categorical variables were analysed using χ² test. MEAV values were estimated using log-transformed up-down independent pairs analysis and probit regression. Significance was assumed at P<0.05 (two-sided).
Results: The MEAV required to provide effective analgesia was significantly (P=0.034) reduced to 0.9 ml [95% confidence interval (CI) 0.3-2.8] in the US group from 5.4 ml (95% CI 3.4-8.6) in the NS group. Fewer needle passes were needed to identify the brachial plexus with US (1 vs 3; P<0.0001) and patients had less pain at 30 min after surgery (P=0.03).
Conclusions: US reduces the number of attempts, LA volume, and postoperative pain when compared with NS for ISB.
Comment in
-
Ultrasound reduces the minimum effective local anaesthetic volume.Br J Anaesth. 2011 Apr;106(4):600; author reply 601-2. doi: 10.1093/bja/aer051. Br J Anaesth. 2011. PMID: 21421606 No abstract available.
-
Ultrasound reduces the minimum effective local anaesthetic volume.Br J Anaesth. 2011 Apr;106(4):600-1; author reply 601-2. doi: 10.1093/bja/aer044. Br J Anaesth. 2011. PMID: 21421607 No abstract available.
-
Regional anaesthesia always works--provided you put the right dose of the right drug in the right place.Br J Anaesth. 2011 Jul;107(1):103; author reply 103-4. doi: 10.1093/bja/aer181. Br J Anaesth. 2011. PMID: 21685116 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous