Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Jan;106(1):124-30.
doi: 10.1093/bja/aeq306. Epub 2010 Nov 8.

Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block

Affiliations
Free article
Randomized Controlled Trial

Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block

A McNaught et al. Br J Anaesth. 2011 Jan.
Free article

Abstract

Background: Previous studies have demonstrated that lower local anaesthetic (LA) volumes can be used for ultrasound (US)-guided interscalene brachial plexus block (ISB). However, no study has examined whether US can reduce the volume required when compared with nerve stimulation (NS) for ISB. Our aim was to do this by comparing the minimum effective analgesic volumes (MEAVs).

Methods: After ethics approval and informed consent, patients undergoing shoulder surgery were recruited to this randomized, double-blind, up-down sequential allocation study. The volume used for both US and NS was dependent upon the success or failure of the previous block. Success was defined as a verbal rating score of 0/10, 30 min after surgery. Ten needle passes were allowed before defaulting to the opposite group. Patients received general anaesthesia. Pain scores and analgesic consumption were assessed by a blinded observer. Statistical comparisons of continuous variables were performed using Student's t-test and Mann-Whitney U-test as appropriate. Categorical variables were analysed using χ² test. MEAV values were estimated using log-transformed up-down independent pairs analysis and probit regression. Significance was assumed at P<0.05 (two-sided).

Results: The MEAV required to provide effective analgesia was significantly (P=0.034) reduced to 0.9 ml [95% confidence interval (CI) 0.3-2.8] in the US group from 5.4 ml (95% CI 3.4-8.6) in the NS group. Fewer needle passes were needed to identify the brachial plexus with US (1 vs 3; P<0.0001) and patients had less pain at 30 min after surgery (P=0.03).

Conclusions: US reduces the number of attempts, LA volume, and postoperative pain when compared with NS for ISB.

PubMed Disclaimer

Comment in

Publication types