Rails and anchors: guiding and trapping droplet microreactors in two dimensions
- PMID: 21060946
- DOI: 10.1039/c0lc00104j
Rails and anchors: guiding and trapping droplet microreactors in two dimensions
Abstract
This paper presents a method to control the motion of nanolitre drops in a wide and thin microchannel, by etching fine patterns into the channel's top surface. Such control is possible for drops that are squeezed by the channel roof, by allowing them to reduce their surface energy as they enter into a local depression. The resulting gain in surface energy pulls a drop into the groove such that localized holes can be used as anchors for holding drops, while linear patterns can be used as rails to guide them along complex trajectories. An anchored drop can remain stationary indefinitely, as long as the driving flow rate is below a critical value which depends on the hole and drop sizes. By micro-fabricating holes into a grid pattern, drops can be arrayed and held in the observation field of a microscope against the mean carrier flow. Their contents can then be modulated by gas exchange with the flowing carrier oil. We demonstrate in particular how the pH or the oxygen levels within the drops can be controlled spatially and temporally, either by exposing rows of drops to two streams of oil at different gas concentrations or by periodically switching oil inputs to vary the gas concentration of drops as a function of time. Oxygen control is used to selectively deoxygenate droplets that encapsulate red blood cells from patients suffering from sickle cell disease, in order to study the polymerization of intracellular hemoglobin. Cycles of oxygenation and deoxygenation of anchored droplets induce depolymerization and polymerization of the hemoglobin, thus providing a method to simulate the cycling that takes place in physiological flows.
Similar articles
-
Combining rails and anchors with laser forcing for selective manipulation within 2D droplet arrays.Lab Chip. 2011 Dec 21;11(24):4228-34. doi: 10.1039/c1lc20541b. Epub 2011 Nov 1. Lab Chip. 2011. PMID: 22045291
-
Sickling of red blood cells through rapid oxygen exchange in microfluidic drops.Lab Chip. 2010 Oct 7;10(19):2505-12. doi: 10.1039/c004390g. Epub 2010 Jul 6. Lab Chip. 2010. PMID: 20603684
-
Surfactant solutions and porous substrates: spreading and imbibition.Adv Colloid Interface Sci. 2004 Nov 29;111(1-2):3-27. doi: 10.1016/j.cis.2004.07.007. Adv Colloid Interface Sci. 2004. PMID: 15571660
-
Potential of levitated drops to serve as microreactors for biophysical measurements.Biophys Chem. 2012 May;165-166:1-12. doi: 10.1016/j.bpc.2012.03.008. Epub 2012 Mar 23. Biophys Chem. 2012. PMID: 22498502 Review.
-
Established and experimental treatments for sickle cell disease.Haematologica. 2004 Mar;89(3):348-56. Haematologica. 2004. PMID: 15020275 Review.
Cited by
-
Evaluation of 3D-printed molds for fabrication of non-planar microchannels.Biomicrofluidics. 2021 Apr 19;15(2):024111. doi: 10.1063/5.0047497. eCollection 2021 Mar. Biomicrofluidics. 2021. PMID: 33912266 Free PMC article.
-
Single-Cell Analysis of [18F]Fluorodeoxyglucose Uptake by Droplet Radiofluidics.Anal Chem. 2015 Jul 7;87(13):6667-73. doi: 10.1021/acs.analchem.5b00792. Epub 2015 Jun 15. Anal Chem. 2015. PMID: 26035453 Free PMC article.
-
Chiral lipid bilayers are enantioselectively permeable.Nat Chem. 2021 Aug;13(8):786-791. doi: 10.1038/s41557-021-00708-z. Epub 2021 Jun 10. Nat Chem. 2021. PMID: 34112989 Free PMC article.
-
Measuring single-cell susceptibility to antibiotics within monoclonal bacterial populations.PLoS One. 2024 Aug 1;19(8):e0303630. doi: 10.1371/journal.pone.0303630. eCollection 2024. PLoS One. 2024. PMID: 39088440 Free PMC article.
-
Microfluidic Chamber Design for Controlled Droplet Expansion and Coalescence.Micromachines (Basel). 2020 Apr 10;11(4):394. doi: 10.3390/mi11040394. Micromachines (Basel). 2020. PMID: 32290165 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources