(Non-targeted) radioactive/fluorescent nanoparticles and their potential in combined pre- and intraoperative imaging during sentinel lymph node resection
- PMID: 21063057
- DOI: 10.1088/0957-4484/21/48/482001
(Non-targeted) radioactive/fluorescent nanoparticles and their potential in combined pre- and intraoperative imaging during sentinel lymph node resection
Abstract
One clinical precedent for the use of nanosized imaging agents is the localization of the tumor draining sentinel lymph nodes. In this application, radiocolloids such as (99m)Tc-NanoColl are currently used to plan the surgical procedure and to provide acoustic guidance during the intervention. Additional injections of dyes are common to provide optical surgical guidance. Bimodal imaging agents, which are both radioactive and fluorescent, have the potential to be used for both surgical planning and intraoperative fluorescence guidance towards the sentinel lymph nodes. This review provides an overview of the radioactive, fluorescent, and size properties of (non-targeted) bimodal nanoparticles, and their (potential) value in sentinel lymph node detection.
Similar articles
-
Sentinel lymph node mapping of the gastrointestinal tract by using invisible light.Ann Surg Oncol. 2006 Mar;13(3):386-96. doi: 10.1245/ASO.2006.04.025. Epub 2006 Jan 31. Ann Surg Oncol. 2006. PMID: 16485157
-
SPECT-CT for topographic mapping of sentinel lymph nodes prior to gamma probe-guided biopsy in head and neck squamous cell carcinoma.J Craniomaxillofac Surg. 2004 Dec;32(6):343-9. doi: 10.1016/j.jcms.2004.05.008. J Craniomaxillofac Surg. 2004. PMID: 15555515
-
Detection of sentinel node in gastric cancer surgery by indocyanine green fluorescence imaging: comparison with infrared imaging.Ann Surg Oncol. 2008 Jun;15(6):1640-3. doi: 10.1245/s10434-008-9872-7. Epub 2008 Apr 1. Ann Surg Oncol. 2008. PMID: 18379850
-
Functional imaging in penile cancer: PET/computed tomography, MRI, and sentinel lymph node biopsy.Curr Opin Urol. 2008 Jan;18(1):105-10. doi: 10.1097/MOU.0b013e3282f151fd. Curr Opin Urol. 2008. PMID: 18090498 Review.
-
Sentinel lymph node biopsy for prostate cancer: a hybrid approach.J Nucl Med. 2013 Apr;54(4):493-6. doi: 10.2967/jnumed.112.113746. Epub 2013 Mar 14. J Nucl Med. 2013. PMID: 23492883 Review.
Cited by
-
Molecularly targeted nanoparticles: an emerging tool for evaluation of expression of the receptor for advanced glycation end products in a murine model of peripheral artery disease.Cell Mol Biol Lett. 2021 Mar 16;26(1):10. doi: 10.1186/s11658-021-00253-0. Cell Mol Biol Lett. 2021. PMID: 33726678 Free PMC article.
-
Concomitant radio- and fluorescence-guided sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity using ICG-(99m)Tc-nanocolloid.Eur J Nucl Med Mol Imaging. 2012 Jul;39(7):1128-36. doi: 10.1007/s00259-012-2129-5. Epub 2012 Apr 18. Eur J Nucl Med Mol Imaging. 2012. PMID: 22526966 Clinical Trial.
-
Hybrid peptide dendrimers for imaging of chemokine receptor 4 (CXCR4) expression.Mol Pharm. 2011 Dec 5;8(6):2444-53. doi: 10.1021/mp200401p. Epub 2011 Nov 15. Mol Pharm. 2011. PMID: 22085282 Free PMC article.
-
Diagnostic accuracy of combined optical- and radio-guided SNB for neck staging of oral squamous cell carcinoma lesions in the anterior oral cavity.Eur Arch Otorhinolaryngol. 2023 Jul;280(7):3393-3403. doi: 10.1007/s00405-023-07939-5. Epub 2023 Apr 3. Eur Arch Otorhinolaryngol. 2023. PMID: 37010601 Free PMC article.
-
U-SPECT-BioFluo: an integrated radionuclide, bioluminescence, and fluorescence imaging platform.EJNMMI Res. 2014 Oct 11;4:56. doi: 10.1186/s13550-014-0056-0. eCollection 2014. EJNMMI Res. 2014. PMID: 25386389 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical