Comparison of technetium-99m-HM-PAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis
- PMID: 2106576
Comparison of technetium-99m-HM-PAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis
Abstract
Technetium-99m-HM-PAO [( 99mTc]HM-PAO) leukocyte and indium-111-oxine (111In-oxine) leukocyte scanning were carried out simultaneously in 41 patients at 4 hr and 24 hr after reinjection to determine whether the 4-hr 99mTc scan could replace the 24-hr 111In scan for detecting intraabdominal sepsis. Abdominal infection was confirmed in 12 cases. The 4-hr 99Tc-leukocyte scan, the 4-hr 111In-leukocyte scan, and the 24-hr 111In-leukocyte scan yielded a sensitivity of 100%, 67%, and 100%, respectively, and a specificity of 62%, 90%, and 86%, respectively. The 24-hr 99mTc-leukocyte scan also produced a sensitivity of 100%, but it was falsely positive in all 29 cases without infection due to physiologic bowel uptake. False-positive 4-hr 99mTc-leukocyte scans were also produced by physiologic bowel uptake in seven cases all of whom had true-negative 4-hr and 24-hr 111In-leukocyte scans. Because of the high incidence of false-positive 4-hr [99mTc]HM-PAO leukocyte scans, it was concluded that they could not replace 24-hr 111In-leukocyte scans for detecting intraabdominal sepsis, and that serial 99mTc leukocyte scans starting earlier than 4 hr after reinjection must be evaluated.
Comment in
-
The usefulness of the 1-hour technetium-99m-HMPAO leukocyte scan in the early diagnosis of acute abdominal sepsis.J Nucl Med. 1990 Oct;31(10):1743-4. J Nucl Med. 1990. PMID: 2213202 No abstract available.
-
In search of the hot appendix--a clinician's view of inflammation imaging.J Nucl Med. 1990 Mar;31(3):316-8. J Nucl Med. 1990. PMID: 2308002 No abstract available.
Similar articles
-
Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease.Eur J Nucl Med. 1993 Mar;20(3):195-200. doi: 10.1007/BF00169998. Eur J Nucl Med. 1993. PMID: 8462606
-
99mTc-HM-PAO for leukocyte labeling--experimental comparison with 111In oxine in dogs.Eur J Nucl Med. 1987;13(7):353-7. doi: 10.1007/BF00252994. Eur J Nucl Med. 1987. PMID: 3123237
-
[Significance of leukocyte scintigraphy of the infected total endoprosthesis].Rofo. 1989 Mar;150(3):284-9. doi: 10.1055/s-2008-1047024. Rofo. 1989. PMID: 2538877 German.
-
Clinical imaging with indium 111 oxine-labeled leukocyte scan: review and case report.Clin Podiatr Med Surg. 1988 Apr;5(2):329-40. Clin Podiatr Med Surg. 1988. PMID: 3129172 Review.
-
Investigation of suspected intra-abdominal sepsis: the contribution of nuclear medicine.Scand J Gastroenterol Suppl. 1994;203:11-4. doi: 10.3109/00365529409091389. Scand J Gastroenterol Suppl. 1994. PMID: 7973441 Review.
Cited by
-
Value of positive technetium-99m leucocyte scans in predicting intestinal inflammation.Gut. 1991 Dec;32(12):1502-7. doi: 10.1136/gut.32.12.1502. Gut. 1991. PMID: 1773957 Free PMC article.
-
Labelled leucocyte scintigraphy in inflammatory bowel disease: clinical applications.Gut. 1996 Jan;38(1):1-5. doi: 10.1136/gut.38.1.1. Gut. 1996. PMID: 8566834 Free PMC article. No abstract available.
-
Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease.Eur J Nucl Med. 1993 Mar;20(3):195-200. doi: 10.1007/BF00169998. Eur J Nucl Med. 1993. PMID: 8462606
-
Comparison of 99m technetium hexamethylpropylene-amine oxime labelled leucocyte with 111-indium tropolonate labelled granulocyte scanning and ultrasound in the diagnosis of intra-abdominal abscess.Gut. 1995 Oct;37(4):557-64. doi: 10.1136/gut.37.4.557. Gut. 1995. PMID: 7489945 Free PMC article.
-
Tc-99m HMPAO labelled WBCs in the detection of occult sepsis in the intensive care unit.Intensive Care Med. 1992;18(1):15-9. doi: 10.1007/BF01706420. Intensive Care Med. 1992. PMID: 1578041
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical