Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Jan;4(1):51-8.
doi: 10.1161/CIRCIMAGING.110.957399. Epub 2010 Nov 10.

Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study

Affiliations
Comparative Study

Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study

Alessia Gimelli et al. Circ Cardiovasc Imaging. 2011 Jan.

Abstract

Background: A novel technology has been developed for ultrafast (UF) single-photon emission CT (SPECT) myocardial perfusion imaging by using a pinhole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coronary artery disease.

Methods and results: A total of 34 patients underwent single-day (99m)Tc-tetrofosmin stress/rest myocardial perfusion imaging. UF-SPECT was performed 10 minutes before S-SPECT. Images were qualitatively analyzed, and the summed stress score and summed rest score were calculated. The segmental tracer uptake value (percentage of maximum myocardial uptake) also was quantified for both UF- and S-SPECT. When only 29 of 34 patients with significant coronary lesions were analyzed, the summed stress score was 10.1±4.4 versus 6.4±2.9, respectively, for UF- and S-SPECT (P=0.002). Qualitative and quantitative per-patient analysis showed similar results in detection of coronary artery disease for UF- and S-SPECT. In contrast, per-vessel analysis demonstrated higher regional sensitivity of UF- versus S-SPECT. UF-SPECT showed higher sensitivity in detecting multivessel disease (P=0.003) versus S-SPECT.

Conclusions: This pilot study confirms that UF-SPECT provides high-quality fast myocardial perfusion imaging and suggests that it may allow a more-accurate evaluation of both extent and severity of myocardial ischemia in patients with coronary artery disease.

PubMed Disclaimer

Comment in

  • New toys for nuclear cardiologists.
    Miller TD, Askew JW, O'Connor MK. Miller TD, et al. Circ Cardiovasc Imaging. 2011 Jan;4(1):5-7. doi: 10.1161/CIRCIMAGING.110.961987. Circ Cardiovasc Imaging. 2011. PMID: 21245363 No abstract available.

Publication types