Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Dec;33(7):E132-E137.
doi: 10.1055/s-0029-1245724. Epub 2010 Nov 15.

Ultrasound guidance for neuraxial analgesia and anesthesia in obstetrics: a quantitative systematic review

Affiliations
Comparative Study

Ultrasound guidance for neuraxial analgesia and anesthesia in obstetrics: a quantitative systematic review

A Schnabel et al. Ultraschall Med. 2012 Dec.

Abstract

Purpose: The aim of this quantitative systematic review was to assess the efficacy and safety of ultrasound-guided neuraxial blocks in obstetric analgesia and anesthesia.

Materials and methods: A systematic search for clinical trials investigating the efficacy and safety of ultrasound-assisted neuraxial blocks in comparison to any other technique was performed in MEDLINE, EMBASE, CINAHL and CENTRAL. Relative risks (RR) were calculated for dichotomous data (e. g. number of patients with vascular punctures), and mean differences (MD) were calculated for continuous outcomes (e. g. number puncture attempts), along with the respective 95 % confidence intervals (95 % CI).

Results: Six clinical trials (published between 2001 and 2009) including the data of 659 patients satisfied the inclusion criteria. Ultrasound-facilitated neuraxial blocks required a lower number of puncture attempts (MD: -0.92; 95 % CI: -1.11 to -0.74; p < 0.00001) and fewer puncture levels (MD: -0.2; 95 % CI: -0.31 to -0.1; p = 0.0002) in comparison with the more conventional loss of resistance. The success rate with the first attempt under ultrasound guidance in supposedly difficult patients was 71 % in comparison to 20 % using a conventional technique. Patients receiving ultrasound-assisted neuraxial blocks had a lower rate of procedure-related complications (post-dural puncture headache, spinal or vascular puncture).

Conclusion: There is some evidence that ultrasound guidance may improve the efficacy and safety of neuraxial blocks in obstetrics. If technical difficulties are anticipated, ultrasound may lower the rate of procedure-related adverse events.