Visco-fracture technique for soft lens cataract removal
- PMID: 21081262
- DOI: 10.1016/j.jcrs.2010.10.032
Visco-fracture technique for soft lens cataract removal
Abstract
We describe a visco-fracture technique for soft nucleus phacoemulsification. Following continuous curvilinear capsulorhexis, cortical cleavage hydrodissection, and hydrodelineation, an ophthalmic viscosurgical device (OVD) is delivered into the eye through a hydrodissection cannula. A small amount of pressure is used to introduce the cannula into the nucleus. The OVD is then gently injected, creating a small central crack. The surgeon can explore this initial crack, enlarging it in both directions to create a complete fracture of the nucleus. The maneuver can be repeated by rotating the nucleus 90 degrees, creating additional fractures in the same way. Each quadrant can then be emulsified using an auxiliary second instrument.
Financial disclosure: Neither author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Comment in
-
Visco-fracture technique for phacoemulsification.J Cataract Refract Surg. 2011 May;37(5):978; author reply 978-9. doi: 10.1016/j.jcrs.2011.03.019. J Cataract Refract Surg. 2011. PMID: 21511172 No abstract available.
Similar articles
-
Visco-fracture technique for phacoemulsification.J Cataract Refract Surg. 2011 May;37(5):978; author reply 978-9. doi: 10.1016/j.jcrs.2011.03.019. J Cataract Refract Surg. 2011. PMID: 21511172 No abstract available.
-
Ophthalmic viscosurgical device-assisted sutureless-incision cataract surgery for a hard nucleus or mature cataract.J Cataract Refract Surg. 2014 Apr;40(4):517-20. doi: 10.1016/j.jcrs.2014.01.026. Epub 2014 Feb 26. J Cataract Refract Surg. 2014. PMID: 24581975
-
Bowl-and-snail technique for soft cataract.J Cataract Refract Surg. 2011 Jan;37(1):8-10. doi: 10.1016/j.jcrs.2010.10.027. J Cataract Refract Surg. 2011. PMID: 21183096
-
[20 rules for hard nucleus phacoemulsification].Oftalmologia. 2005;49(1):6-7. Oftalmologia. 2005. PMID: 15934328 Review. Romanian.
-
Phacoemulsification of the rock-hard dense nuclear cataract: Options and recommendations.J Cataract Refract Surg. 2018 Jul;44(7):905-916. doi: 10.1016/j.jcrs.2018.03.038. Epub 2018 Jun 28. J Cataract Refract Surg. 2018. PMID: 29960655 Review.
Cited by
-
A rapid technique for en masse soft cataract phacoemulsification.Clin Ophthalmol. 2019 Apr 26;13:755-762. doi: 10.2147/OPTH.S197359. eCollection 2019. Clin Ophthalmol. 2019. PMID: 31114153 Free PMC article.
-
Two-speed phacoemulsification for soft cataracts using optimized parameters and procedure step toolbar with the CENTURION Vision System and Balanced Tip.Clin Ophthalmol. 2015 Aug 27;9:1563-72. doi: 10.2147/OPTH.S90245. eCollection 2015. Clin Ophthalmol. 2015. PMID: 26355695 Free PMC article.
-
One-handed revolving technique for soft cataract extraction.Clin Ophthalmol. 2018 Nov 27;12:2423-2425. doi: 10.2147/OPTH.S184229. eCollection 2018. Clin Ophthalmol. 2018. PMID: 30568420 Free PMC article.
-
Diagnostic Considerations in Compressive Neuropathies.J Hand Surg Glob Online. 2022 Dec 16;5(4):525-535. doi: 10.1016/j.jhsg.2022.10.010. eCollection 2023 Jul. J Hand Surg Glob Online. 2022. PMID: 37521550 Free PMC article. Review.
-
Zero Phaco: A new technique for dealing with soft cataracts.Indian J Ophthalmol. 2022 Oct;70(10):3673-3676. doi: 10.4103/ijo.IJO_1149_22. Indian J Ophthalmol. 2022. PMID: 36190070 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources