A folding-based electrochemical aptasensor for detection of vascular endothelial growth factor in human whole blood
- PMID: 21081271
- DOI: 10.1016/j.bios.2010.10.029
A folding-based electrochemical aptasensor for detection of vascular endothelial growth factor in human whole blood
Abstract
We herein report a folding-based electrochemical DNA aptasensor for the detection of vascular endothelial growth factor (VEGF) directly in complex biological samples, including blood serum and whole blood. The electrochemical signal generation is coupled to a large, target-induced conformational change in a methylene blue-modified and surface immobilized anti-VEGF aptamer. The sensor is sensitive, selective and essentially reagentless: we can readily detect VEGF down to 5 pM (190 pg/mL) directly in 50% blood serum. Similar to other aptasensors of this class, the VEGF sensor is also regenerable and reusable. In addition, the sensor performs comparably well even when fabricated on a gold-plated screen-printed carbon electrode and can potentially be implemented as a cost-effective, single-use biosensor for diseases diagnosis and therapy monitoring. The exceptional sensitivity, selectivity, and reusability of this electrochemical aptasensor platform suggest it may be a promising strategy for a wide variety of sensing applications.
Copyright © 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Fabricated aptamer-based electrochemical "signal-off" sensor of ochratoxin A.Biosens Bioelectron. 2010 Oct 15;26(2):710-6. doi: 10.1016/j.bios.2010.06.058. Biosens Bioelectron. 2010. PMID: 20643539
-
Aptamer-based electrochemical detection of picomolar platelet-derived growth factor directly in blood serum.Anal Chem. 2007 Jan 1;79(1):229-33. doi: 10.1021/ac061592s. Anal Chem. 2007. PMID: 17194144
-
Impedimetric aptasensor for tobramycin detection in human serum.Biosens Bioelectron. 2011 Jan 15;26(5):2354-60. doi: 10.1016/j.bios.2010.10.011. Epub 2010 Oct 14. Biosens Bioelectron. 2011. PMID: 21051217
-
Aptamer-based biosensors and nanosensors for the detection of vascular endothelial growth factor (VEGF): A review.Biosens Bioelectron. 2018 Jul 1;110:23-37. doi: 10.1016/j.bios.2018.03.037. Epub 2018 Mar 19. Biosens Bioelectron. 2018. PMID: 29579646 Review.
-
A novel electrochemical aptasensor for ultrasensitive detection of kanamycin based on MWCNTs-HMIMPF6 and nanoporous PtTi alloy.Biosens Bioelectron. 2015 Dec 15;74:691-7. doi: 10.1016/j.bios.2015.06.081. Epub 2015 Jul 10. Biosens Bioelectron. 2015. PMID: 26208174 Review.
Cited by
-
Aptamers: a novel targeted theranostic platform for pancreatic ductal adenocarcinoma.Radiat Oncol. 2020 Aug 5;15(1):189. doi: 10.1186/s13014-020-01624-1. Radiat Oncol. 2020. PMID: 32758252 Free PMC article. Review.
-
Three-dimensional hierarchical plasmonic nano-architecture enhanced surface-enhanced Raman scattering immunosensor for cancer biomarker detection in blood plasma.ACS Nano. 2013 Jun 25;7(6):4967-76. doi: 10.1021/nn4018284. Epub 2013 May 14. ACS Nano. 2013. PMID: 23659430 Free PMC article.
-
Use of Silicon Nanowire Sensors for Early Cancer Diagnosis.Molecules. 2021 Jun 18;26(12):3734. doi: 10.3390/molecules26123734. Molecules. 2021. PMID: 34207397 Free PMC article. Review.
-
Collagen Membranes with Ribonuclease Inhibitors for Long-Term Stability of Electrochemical Aptamer-Based Sensors Employing RNA.Anal Chem. 2017 May 16;89(10):5598-5604. doi: 10.1021/acs.analchem.7b00766. Epub 2017 May 3. Anal Chem. 2017. PMID: 28440619 Free PMC article.
-
Single-step nanoplasmonic VEGF165 aptasensor for early cancer diagnosis.ACS Nano. 2012 Sep 25;6(9):7607-14. doi: 10.1021/nn203833d. Epub 2012 Aug 21. ACS Nano. 2012. PMID: 22880609 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources